Pulling glass pipettes for the Nanoject

Use the Narishige PC-100 in the patch room:

image

Make sure to use the Drummond 3.5" #3-000-203-G/X glass capillary tube, and not a patch capillary tube:

image

Insert the glass capillary into the PC-100 with ~1-2cm protruding from the top. The capillary should go through the metal heating element. Secure with the top thumb screw to hold the capillary in place:

image

Lift the weighted bottom piece up and clamp it onto the glass capillary with the thumb screw:

image

Push the "Step 1" button - we're doing a 1 step pull:

image

Close the cover and hit the red "Start" button - the heating element will heat up:

image

Once the weight drops and pulls the pipette, cut the thin glass in the middle to separate the two parts:

image

The bottom piece is the good pipette. The top piece will be curved and unusable so put it in the sharps:

image

Place the good pipette in a dish with clay to secure it and make more!

image

🧠 Home


📘 General Information

EHS and DCM procedures

🐭 Animal policies


🧪 Experimental Protocols

Weighing mice and food

✂️ Intracranial Surgical Protocols

✂️ Other Surgical Protocols

🩸 Blood collection

🍬 Glucose tolerance testing

Intracranial injections

🧬 Biomolecular protocols

Von Frey testing

🧬 Virus Injections

💡 Photometry

Acquisition

Analysis

In vivo electrophysiology

🧪 Pharmacology

Behavior Chambers

Bonsai workflows

🔬 Histology

Microscopy


Devices

🛠️ Arduino

Sippers

Tumble Feeder

Social Door


📊 Data Analysis

Electrophysiology

Ex Vivo

In Vivo


🎥 Imaging

Miniscopes

1P Imaging with Mightex OASIS


🧱 Miscellaneous Tools

Clone this wiki locally