SWHC046 Packaged Heat Pump Air Conditioner Commercial, Fuel Substitution - new measure #83
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
Show all changes
58 commits
Select commit
Hold shift + click to select a range
c566784
Created a new measure folder for SWHC046
behzadsalimian 530d457
Included the cases file for SWHCO46
behzadsalimian a0a309e
Modified the untary.pxt to correct missing input field for Coil:Heati…
behzadsalimian 6ed7f68
Added hourly variable for QC of SWHC046
behzadsalimian 225c72f
Updated input parameters
behzadsalimian a664eb8
Updated input parameters for Htl building
behzadsalimian 6e57430
Updated the cases files
behzadsalimian bf5af83
Renamed the folder, Updated vintages.
behzadsalimian 7cb8cfc
Updated the weather files
behzadsalimian 6cc2463
Merge branch 'main' into SWHC046-workingcopy1
behzadsalimian 38ac0aa
Renamed cohorts with new naming convention (2024-05-13)
simularis f954f99
Update cases including case_name and main_cool_coil_cop (2024-05-24)
simularis 7880aa7
Merge branch 'main' into SWHC046-Candidate2
behzadsalimian f8cd3d4
Revised cases files to include TRC system types and QC'd COP values.
behzadsalimian 545900e
Added helper file for creating cases for all building types at the sa…
behzadsalimian d7a4074
Added queries for extracting data from the simulation results.
behzadsalimian a2866e0
README file for SWHC046 processing
simularis 6399ca6
Revise README
simularis dd29225
Include measure list for SWHC046-candidate2
simularis 52f73d4
Merge pull request #10 from behzadsalimian/SWHC046-Candidate2
simularis 3536afc
Merge pull request #12 from simularis/swhc046-candidate2-post-proc
simularis e6209da
Changed fan speed control and heat and cool sizing factors
0a39739
Added 4 baseline cases with variable fan speed control and changed he…
358a52b
Changed heat and cool sizing factors
da49e0b
Revise create_hvac_copies.cmd and cDXHP.csv file for creating case files
8fbe587
Remove unused case files
4b5b16a
Update heat and cool sizing factors for Htl case file
f3284d7
Update code file for Htl climates.csv to T24_weight_averaged_ex_Htl.csv
4e392b2
Remove lines for the unused cases files
0cb19d5
Update post-processing scripts
bd900f2
Bug fix for #122
nfette bbe1bf9
Debug PSQL post-process script for SWHC046
nfette 75cd97d
Update standard query files in SWHC046 for compatibility with Com.py
simularis c2d735c
QC query files for simdata process
simularis 355ef5a
Revert unnecessary changes from 2025-09-24
simularis 40f2fa0
Merge branch 'bugfix-122' of https://github.com/simularis/DEER-Protot…
simularis f9ee1d0
Renamed query files for sizing
simularis ba13605
Simplified query files for sizing
simularis e5fd52d
Document cooling coil capacity calculation process for SWHC046
nfette 584b78c
Include query string for multispeed cooling coils
nfette 953d804
Clarify arguments to insert_normunit script for SWHC046
nfette d2632f1
Clarify sizing column name in SWHC046
nfette ee220c6
Merge pull request #37 from simularis/dev-SWHC046-VarFan
nfette 068a79d
Switch cooling capacity query from Coil:Cooling to AirLoopHVAC:Unitar…
simularis 08f3076
Convert main HVAC filter from coil to system and column "object"
nfette c591590
Clarifications to SWHC046 post-processing README
nfette fe2c887
Streamline and update result_filtered script for compatibility with m…
nfette 99b4293
Get simulation metadata in sizing_agg_filtered SWHC046
nfette 76a5a17
Update query files to show just cooling capacity
122e04d
Update README.md
c89c45f
Update DEER_EnergyPlus_Modelkit_Measure_list_working.xlsx
70b7558
Revert "Update DEER_EnergyPlus_Modelkit_Measure_list_working.xlsx"
nfette ae1ae4c
Merge pull request #42 from simularis/dev-SWHC046-VarFan
nfette 5dbb5d8
Move "commercial measures/SWHC046-04 Pkg HP AC Com" to -06
nfette c8e2b50
Move SWHC046 subfolders from -04 to -06
nfette cb04ada
Rename folders in SWHC046-06 measure list workbook
nfette 62ef4ea
Update subfolder paths hard-coded in script for SWHC046
nfette 7520cb4
Merge pull request #52 from simularis/dev-SWHC046-rename-folder-06
simularis File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
24 changes: 24 additions & 0 deletions
24
commercial measures/SWHC046-06 Pkg HP AC Com/.modelkit-config
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,24 @@ | ||
|
|
||
| # Paths are expanded relative to this modelkit-config file. | ||
|
|
||
| prototypes-dir = '../../prototypes' | ||
| templates-dir = '../../templates/energyplus/templates' | ||
| weather-dir = '../../weather' | ||
| codes-dir = '../../codes' | ||
|
|
||
| max-workers = 12 # Maximum number of simulations to run in parallel | ||
|
|
||
|
|
||
| [template-compose] | ||
| annotate = true | ||
| indent = " " | ||
| esc-line = "! " | ||
| dirs = '~\Documents\Modelkit Caboodle\templates\energyplus\templates' # Must be an absolute path | ||
|
|
||
| [energyplus-run] | ||
| engine = 'C:\EnergyPlusV22-2-0' # Must be an absolute path | ||
| #engine = '/Applications/EnergyPlus-22-2-0' # Must be an absolute path | ||
| #engine = '/Applications/EnergyPlus-9-2-0' # Must be an absolute path | ||
| readvars = true | ||
| keep = false | ||
| output-files = "eplusout.err; eplusout.sql; eplustbl.htm; eplusvar.csv" |
Binary file added
BIN
+743 KB
...cial measures/SWHC046-06 Pkg HP AC Com/DEER_EnergyPlus_Modelkit_Measure_list_working.xlsx
Binary file not shown.
simularis marked this conversation as resolved.
Show resolved
Hide resolved
|
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,126 @@ | ||
| # Steps to run simulations, gather outputs, and post-process results for this measure | ||
|
|
||
| Note if `result2.py` is not present, see https://github.com/sound-data/DEER-Prototypes-EnergyPlus/pull/65. | ||
|
|
||
| ``` | ||
| REM In command prompt, change directory to a clone of the repository. You may have a different path. | ||
| cd "C:/DEER-Prototypes-EnergyPlus" | ||
| ``` | ||
|
|
||
| ## 1. Run simulations and generate output files | ||
|
|
||
| ### 1.1. Run simulations | ||
|
|
||
| ``` | ||
| cd "commercial measures/SWHC046-04 Pkg HP AC Com/SWHC046-04 Pkg HP AC Com_Ex" | ||
| modelkit rake compose | ||
| REM For large number of simulations, rakefile may fail to gather results, so just run simulations. | ||
| modelkit rake run | ||
| ``` | ||
|
|
||
| Then, repeat for subfolder `SWHC046-04 Pkg HP AC Com_Htl_Ex`. | ||
|
|
||
| Optionally, while `modelkit rake run` is running, use how-to-track-progress.py to see a progress bar. | ||
|
|
||
| Optionally, after model runs are complete, use | ||
| [QC incomplete simulations.ipynb](https://github.com/simularis/building-energy-utils/blob/main/deer-user-scripts/QC%20incomplete%20simulations.ipynb) | ||
| to get statistics on failed simulations and a count of warning and error messages from EnergyPlus. | ||
|
|
||
| ### 1.2. Gather summary output files for raw usage and QC | ||
|
|
||
| #### Generate results-summary.csv (using standard query file, for use with post-process scripts) | ||
|
|
||
| Option 1 (using modelkit). If option 1 fails, try option 2. | ||
|
|
||
| ``` | ||
| modelkit rake results | ||
| ``` | ||
|
|
||
| Option 2 (using equivalent python script) | ||
|
|
||
| ``` | ||
| cd "commercial measures/SWHC046-04 Pkg HP AC Com/SWHC046-04 Pkg HP AC Com_Ex" | ||
| python "../../../scripts/result.py" . --queryfile "query.txt" --detailfile results-sizing-detail.csv --aggfile results-summary.csv | ||
| ``` | ||
|
|
||
| Note that the python script has a side effect of outputting a file with disaggregated quantities for any query items that represent aggregate totals, such as cooling capacity of all coils. | ||
|
|
||
| Repeat for each subfolder (`SWHC046-04 Pkg HP AC Com_Ex` and `SWHC046-04 Pkg HP AC Com_Htl_Ex`). | ||
|
|
||
| #### Generate customized simdata.csv | ||
|
|
||
| ``` | ||
| cd "commercial measures/SWHC046-04 Pkg HP AC Com/" | ||
| python "result2.py" . --queryfile "query_SWHC046_QC.txt" | ||
| ``` | ||
|
|
||
| The dot represents the current directory. This script runs outside the vintage subfolders, so only run this script once. | ||
|
|
||
| Use simdata.csv to perform QC, calculate UEC for all categories of load, and obtain DEER Peak Demand results bypassing the post-processing tool. | ||
|
|
||
| ## 2. Determine cooling capacity subject to measure | ||
|
|
||
| ### 2.1. Extract cooling capacity from every coil in model | ||
|
|
||
| Extract results to results-sizing-detail.csv | ||
|
|
||
| ``` | ||
| cd "commercial measures/SWHC046-04 Pkg HP AC Com/SWHC046-04 Pkg HP AC Com_Ex" | ||
| python "../../../scripts/result.py" . --queryfile "query_SWHC046_sizing.txt" --detailfile results-sizing-detail.csv --aggfile results-sizing-agg.csv | ||
| ``` | ||
|
|
||
| Repeat for each vintage subfolder "SWHC046-04 Pkg HP AC Com_Htl_Ex". | ||
|
|
||
| ### 2.2. Filter cooling capacity | ||
|
|
||
| Filter and aggregate results into sizing_agg_filtered.csv. Note that this step depends on the file coil_list.xlsx being in the same folder as the script. | ||
|
|
||
| ``` | ||
| cd "commercial measures/SWHC046-04 Pkg HP AC Com" | ||
| python result_filtered.py | ||
| ``` | ||
|
|
||
| ## 3. Apply post-processing for commercial sector weighted average (with normalizing units from models) | ||
|
|
||
| For commercial sector weighted averages, post-process according to instructions in [../../scripts](../../scripts). The command line steps include: | ||
|
|
||
| ### 3.1 Run data transformation script to get current_msr_mat, sim_annual, and sim_hourly_wb | ||
|
|
||
| First, copy the DEER_EnergyPlus_Modelkit_Measure_list workbook from this folder into "C:/DEER-Prototypes-EnergyPlus/scripts/data transformation". Then, follow the standard procedures for data transformation per instructions in [../../scripts](../../scripts). | ||
|
|
||
| ``` | ||
| cd "C:/DEER-Prototypes-EnergyPlus" | ||
| cd "scripts/data transformation" | ||
| REM Generate current_msr_mat.csv, sim_annual.csv, and sim_hourly_wb.csv. | ||
| python Com.py | ||
| REM Optionally, copy the outputs to the measure folder | ||
| copy "current_msr_mat.csv" "commercial measures/SWHC046-04 Pkg HP AC Com" | ||
| copy "sim_annual.csv" "commercial measures/SWHC046-04 Pkg HP AC Com" | ||
| copy "sim_hourly_wb.csv" "commercial measures/SWHC046-04 Pkg HP AC Com" | ||
| ``` | ||
|
|
||
| ### 3.2. Insert results from cooling capacity into sim_annual | ||
|
|
||
| The script insert_normunits.py inserts results from sizing_agg_filtered.csv into a copy of sim_annual.csv and saves it to sim_annual_withunits.csv. The command line pattern for this script is: | ||
|
|
||
| ``` | ||
| python insert_normunits.py <sizing_column> <normunit> <conversion_factor> <measure_name> | ||
| ``` | ||
|
|
||
| For this measure the options are | ||
| - `<sizing_column>` = "Cooling Capacity (W)" | ||
| - `<normunit>` = Cap-Tons | ||
| - `<conversion_factor>` = (W thermal / 1 ton cooling) = 1 / 3516.85284 = 2.84345e-4 | ||
| - `<measure_name>` = "Pkg HP AC Com" | ||
|
|
||
| First copy the sizing_agg_filtered.csv into the scripts folder. Then run the script: | ||
|
|
||
| ``` | ||
| python insert_normunits.py "Cooling Capacity (W)" Cap-Tons 2.84345e-4 "Pkg HP AC Com" | ||
| ``` | ||
|
|
||
| At this point, you should have an updated copy of sim_annual.csv with cooling capacity in the normalizing units column. | ||
|
|
||
| ### 3.3. Run commercial post-processing script | ||
|
|
||
| Refer to standard instructions in [../../scripts](../../scripts). Use the file "sim_annual_withunits.xlsx" in place of the "sim_annual.csv" file from Com.py. |
23 changes: 23 additions & 0 deletions
23
...-06 Pkg HP AC Com/SWHC046-06 Pkg HP AC Com_Ex/cases/Asm&0&cDXHP&Ex&dxHP_equip__pkgEER.csv
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,23 @@ | ||
| skip,case_name,sizing_case,:heat_sizing_factor,:cool_sizing_factor,:hvac_config,:main_hvac_type,:main_atu_reheat_coil_type,:main_atu_reheat_control,:main_fan_rise,:main_cool_coil_type,:main_heat_coil_type,:main_dx_type,:main_sat_reset_type,:main_sat_temp_max,:main_design_peak_load,:main_oa_econ_type,:main_cool_coil_cop,:main_dx_comp_speed,:main_cool_flow_min_frac,:main_unitary_no_load_flow_method,:main_fan_speed,:main_fan_motor_eff,:main_heat_coil_cop,:main_heat_coil_eff,:main_heat_flow_frac,:chw_chiller_cop,:chw_chiller_model,:chw_pump_type,:hw_boiler_eff | ||
| ,NE-dxAC_equip-pkgEER-14.2-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.91,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-13.2-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.74,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-14.8-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.07,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgSEER-13.4-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.82,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-12.2-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.6,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-11.4-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.36,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-12.7-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.59,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgSEER-12.35-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.65,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-14.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.95,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-15.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.11,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-13.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.8,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-14-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.91,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-15-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.11,CONSTANT,,,CONSTANT,0.87,3.61,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-16-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.34,CONSTANT,,,CONSTANT,0.87,3.61,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-15.4-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.27,CONSTANT,,,CONSTANT,0.87,3.93,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-16.3-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.43,CONSTANT,,,CONSTANT,0.87,4.02,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-14.4-SEER2-1Stage,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,CONSTANT,,,CONSTANT,0.87,3.86,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-14.4-SEER2-2Stage,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,DUAL-EQUAL,,,CONSTANT,0.87,3.86,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-14.4-SEER2-8.7-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,CONSTANT,,,CONSTANT,0.87,3.97,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-15.4-SEER2-9-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.27,CONSTANT,,,CONSTANT,0.87,4.02,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-16.3-SEER2-9.4-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.43,CONSTANT,,,CONSTANT,0.87,4.09,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-17.3-SEER2-9.7-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.56,CONSTANT,,,CONSTANT,0.87,4.13,,1,,,, |
27 changes: 27 additions & 0 deletions
27
...-06 Pkg HP AC Com/SWHC046-06 Pkg HP AC Com_Ex/cases/ECC&0&cDXHP&Ex&dxHP_equip__pkgEER.csv
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,27 @@ | ||
| skip,case_name,sizing_case,:heat_sizing_factor,:cool_sizing_factor,:hvac_config,:main_hvac_type,:main_atu_reheat_coil_type,:main_atu_reheat_control,:main_fan_rise,:main_cool_coil_type,:main_heat_coil_type,:main_dx_type,:main_sat_reset_type,:main_sat_temp_max,:main_design_peak_load,:main_oa_econ_type,:main_cool_coil_cop,:main_dx_comp_speed,:main_cool_flow_min_frac,:main_unitary_no_load_flow_method,:main_fan_speed,:main_fan_motor_eff,:main_heat_coil_cop,:main_heat_coil_eff,:main_heat_flow_frac,:chw_chiller_cop,:chw_chiller_model,:chw_pump_type,:hw_boiler_eff | ||
| ,NE-dxAC_equip-pkgEER-14.2-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.91,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-13.2-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.74,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-14.8-IEER-TE-0.81,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.07,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgSEER-13.4-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.82,CONSTANT,,,CONSTANT,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-12.2-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.6,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-11.4-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.36,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-12.7-IEER-TE-0.80,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.59,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxAC_equip-pkgSEER-12.35-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.65,CONSTANT,,,CONSTANT,0.87,,0.8,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-14.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.95,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-15.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.11,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-13.5-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.8,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-14-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.91,CONSTANT,,,CONSTANT,0.87,3.4,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-15-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.11,CONSTANT,,,CONSTANT,0.87,3.61,,1,,,, | ||
| ,NE-dxHP_equip-pkgEER-16-IEER,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.34,CONSTANT,,,CONSTANT,0.87,3.61,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-15.4-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.27,CONSTANT,,,CONSTANT,0.87,3.93,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-16.3-SEER2,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.43,CONSTANT,,,CONSTANT,0.87,4.02,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-14.4-SEER2-1Stage,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,CONSTANT,,,CONSTANT,0.87,3.86,,1,,,, | ||
| ,NE-dxHP_equip-pkgSEER-14.4-SEER2-2Stage,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,DUAL-EQUAL,,,CONSTANT,0.87,3.86,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-14.4-SEER2-8.7-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.12,CONSTANT,,,CONSTANT,0.87,3.97,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-15.4-SEER2-9-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.27,CONSTANT,,,CONSTANT,0.87,4.02,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-16.3-SEER2-9.4-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.43,CONSTANT,,,CONSTANT,0.87,4.09,,1,,,, | ||
| ,NE-dxHP_equip-spltSEER-17.3-SEER2-9.7-HSPF,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,DX-AIR,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.56,CONSTANT,,,CONSTANT,0.87,4.13,,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-14.2-IEER-TE-0.81-VarFan,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.91,CONSTANT,,,VARIABLE,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-13.2-IEER-TE-0.81-VarFan,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.74,CONSTANT,,,VARIABLE,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgEER-14.8-IEER-TE-0.81-VarFan,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,4.07,CONSTANT,,,VARIABLE,0.87,,0.81,1,,,, | ||
| ,NE-dxAC_equip-pkgSEER-13.4-SEER2-VarFan,,1.25,1.15,,SZ-CAV,NONE,nil,3.877['in H2O'],DX-AIR,COMBUSTION,PNNL,FLOATING,95['F'],NONCOINCIDENT,FIXED-DRY-BULB,3.82,CONSTANT,,,VARIABLE,0.87,,0.81,1,,,, |
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Solaris team found a new recommendation for enhancement during QC of most recent changes.
See simularis#53. This is a low priority finding that does not impact models.