Available datapoints depend on the inverter type and on which values the inverter actually sends.
In MQTT and in the JSON output you will mainly see these groups:
-
RawData: original inverter replies and command answers -
EspData: device information, Wi-Fi and MQTT status -
DeviceData: mostly fixed inverter information -
LiveData: current live inverter values and DS18B20 temperature sensors -
Status: connection and status information
With the normal MQTT topic layout:
<MQTT topic>/EspData/<name><MQTT topic>/DeviceData/<name><MQTT topic>/LiveData/<name><MQTT topic>/RAW/<command><MQTT topic>/Alive<MQTT topic>/DeviceControl/Set_Command_answer
With JSON mode:
<MQTT topic>/Data
If Home Assistant discovery is enabled together with JSON mode, the normal MQTT datapoint topics are still published as well.
| Datapoint | Unit | Notes |
|---|---|---|
AC_In_Voltage |
V | Grid or input voltage |
AC_In_Frequenz |
Hz | Grid or input frequency |
AC_Out_Voltage |
V | Inverter output voltage |
AC_Out_Frequenz |
Hz | Inverter output frequency |
AC_Out_VA |
VA | Output apparent power |
AC_Out_Watt |
W | Output active power |
AC_Out_Percent |
% | Output load |
Battery_Voltage |
V | Battery voltage |
Battery_Charge_Current |
A | Charge current |
Battery_Discharge_Current |
A | Discharge current |
Battery_Percent |
% | Battery state of charge if available |
PV_Input_Voltage |
V | PV voltage |
PV_Input_Current |
A | PV current |
PV_Input_Power |
W | PV power |
PV_Charging_Power |
W | Solar charging power |
PV2_Input_Voltage |
V | Second PV tracker voltage |
PV2_Input_Current |
A | Second PV tracker current |
PV2_Input_Power |
W | Second PV tracker power |
SCC_Charge_Power |
W | Charger power if available |
Inverter_Operation_Mode |
text | Standby / line / battery / fault etc. |
Device_Status |
text | Device status text |
Fault_Code |
text | Fault summary |
Warning_Code |
text | Warning summary |
DS18B20_<n> |
°C | External 1-Wire temperature sensors |
| Datapoint | Unit | Notes |
|---|---|---|
Protocol_ID |
text | Detected inverter protocol |
Device_Model |
text | Model string from inverter |
Machine_Type |
text | Inverter type information |
Battery_Rating_Voltage |
V | Nominal battery voltage |
Battery_Bulk_Voltage |
V | Bulk charging voltage |
Battery_Float_Voltage |
V | Float charging voltage |
Battery_Recharge_Voltage |
V | Recharge threshold |
Battery_Redischarge_Voltage |
V | Redischarge threshold |
Current_Max_AC_Charging_Current |
A | AC charging current limit |
Current_Max_Charging_Current |
A | Total charging current limit |
Output_Source_Priority |
text | Output source mode |
Charger_Source_Priority |
text | Charger source mode |
Solar_Power_Priority |
text | PV priority mode |
Typical raw keys include:
QPIQMNQPIRIQPIGSQPIGS2QPIWSQALLQ1CommandAnswer
This section is mainly useful when support or troubleshooting is needed.
- Not every inverter exposes every field.
- Some values may appear under slightly different names depending on the inverter family.
- If a field is missing on your device, that does not automatically mean something is wrong.
If something does not work, start with wiring, settings and the Debug page.
Solar2MQTT is a community project. Some devices work immediately, others need a little troubleshooting and a good debug report.