Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
Show all changes
22 commits
Select commit Hold shift + click to select a range
449e348
Develop 2025 CA Title 24 codes files (#100)
simularis Mar 25, 2025
e6209da
Changed fan speed control and heat and cool sizing factors
Sep 17, 2025
0a39739
Added 4 baseline cases with variable fan speed control and changed he…
Sep 17, 2025
358a52b
Changed heat and cool sizing factors
Sep 17, 2025
da49e0b
Revise create_hvac_copies.cmd and cDXHP.csv file for creating case files
Sep 17, 2025
8fbe587
Remove unused case files
Sep 17, 2025
4b5b16a
Update heat and cool sizing factors for Htl case file
Sep 17, 2025
f3284d7
Update code file for Htl climates.csv to T24_weight_averaged_ex_Htl.csv
Sep 17, 2025
4e392b2
Remove lines for the unused cases files
Sep 19, 2025
0cb19d5
Update post-processing scripts
Sep 25, 2025
bd900f2
Bug fix for #122
nfette Sep 25, 2025
bbe1bf9
Debug PSQL post-process script for SWHC046
nfette Sep 28, 2025
75cd97d
Update standard query files in SWHC046 for compatibility with Com.py
simularis Oct 15, 2025
c2d735c
QC query files for simdata process
simularis Oct 15, 2025
355ef5a
Revert unnecessary changes from 2025-09-24
simularis Oct 15, 2025
40f2fa0
Merge branch 'bugfix-122' of https://github.com/simularis/DEER-Protot…
simularis Oct 15, 2025
f9ee1d0
Renamed query files for sizing
simularis Oct 15, 2025
ba13605
Simplified query files for sizing
simularis Oct 15, 2025
e5fd52d
Document cooling coil capacity calculation process for SWHC046
nfette Oct 20, 2025
584b78c
Include query string for multispeed cooling coils
nfette Oct 20, 2025
953d804
Clarify arguments to insert_normunit script for SWHC046
nfette Oct 21, 2025
d2632f1
Clarify sizing column name in SWHC046
nfette Oct 21, 2025
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
290 changes: 290 additions & 0 deletions codes/T24_2025_MFm.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,290 @@
title: 2025 California Efficiency Standards,,,
# PRESCRIPTIVE ENVELOPE CRITERIA FOR Multi-family homes,,,
# For opaque envelope: see Table 170.2-A,,,
table: Res Key Prototype Values | Climate Zone 1,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.52,,RASS 2019 data
Door,0.2,,U-IP
climate_zone,1,,
,,,
table: Res Key Prototype Values | Climate Zone 2,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.0419186,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,REQ,,
Slab Floor,NR,,
Roofing,NR,,
Vertical Fenestration U-Factor,0.3,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,2,,
,,,
table: Res Key Prototype Values | Climate Zone 3,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.224118,,"SI unit,Option B, R30"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,
Duct Insulation,6,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,REQ,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.5,,RASS 2019 data
Door,0.2,,U-IP
climate_zone,3,,
,,,
table: Res Key Prototype Values | Climate Zone 4,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,4,,
,,,
table: Res Key Prototype Values | Climate Zone 5,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.224118,,"SI unit,Option B, R30"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,R IP
Duct Insulation,6,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,REQ,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.51,,RASS 2019 data
Door,0.2,,U-IP
climate_zone,5,,
,,,
table: Res Key Prototype Values | Climate Zone 6,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.224118,,"SI unit,Option B, R30"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.0886047,,"SI unit, 0.065U"
wall_consol_layer_conductivity,0.0419186,,SI unit
wall_insulation_layer_thickness,0.01905,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,R IP
Duct Insulation,6,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,REQ,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.34,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,6,,
,,,
table: Res Key Prototype Values | Climate Zone 7,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.224118,,"SI unit,Option B, R30"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.0886047,,"SI unit, 0.065U"
wall_consol_layer_conductivity,0.0419186,,SI unit
wall_insulation_layer_thickness,0.01905,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,NR,,R IP
Duct Insulation,6,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,REQ,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.34,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,7,,
,,,
table: Res Key Prototype Values | Climate Zone 8,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.3,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,8,,
,,,
table: Res Key Prototype Values | Climate Zone 9,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.3,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,9,,
,,,
table: Res Key Prototype Values | Climate Zone 10,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,13,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.3,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,10,,
,,,
table: Res Key Prototype Values | Climate Zone 11,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,11,,
,,,
table: Res Key Prototype Values | Climate Zone 12,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.3,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,12,,
,,,
table: Res Key Prototype Values | Climate Zone 13,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,REQ,,"Option B; 0.63 Solar reflect, 0.75 thermal emittance"
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,13,,
,,,
table: Res Key Prototype Values | Climate Zone 14,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,14,,
,,,
table: Res Key Prototype Values | Climate Zone 15,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,19,,R IP
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,NR,,
Roofing,REQ,,"Option B; 0.63 Solar reflect, 0.75 thermal emittance"
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.23,,
Door,0.2,,U-IP
climate_zone,15,,
,,,
table: Res Key Prototype Values | Climate Zone 16,,,
Envelope Component,Value,Extent,Notes
ceil_consol_layer_thickness,0.2838824,,"SI unit,Option B, R38"
ceil_consol_layer_conductivity,0.0476386,,SI unit
wall_consol_layer_thickness,0.076790698,,"SI unit, 0.051U"
wall_consol_layer_conductivity,0.041918605,,SI unit
wall_insulation_layer_thickness,0.0508,,SI unit
wall_insulation_layer_conductivity,0.02884,,SI unit
Below Roof Deck Insulation,13,,
Duct Insulation,8,,"IP unit, R value (Table 170.2-K)"
Radiant Barrier,NR,,
Slab Floor,REQ,,"R7, U 0.58"
Roofing,NR,,Option B
Vertical Fenestration U-Factor,0.28,,IP unit
Vertical Fenestration SHGC,0.5,,RASS 2019 data
Door,0.2,,U-IP
climate_zone,16,,