Full Data Packet

This packet contains all the data generated by the EPS module. It is sent to OBDH upon request.

Position Variable Position Variable
0-1 -Y Panel Current 28-29 Batteries Monitor Temperature
2-3 +X Panel Current 30-31 Battery 1 Voltage
4-5 -X Panel Current 32-33 Battery 2 Voltage
6-7 +Z Panel Current 34-35 Batteries Current
8-9 -Z Panel Current 36-37 Batteries Accumulated Current
10-11 +Y Panel Current 38 Protection Register
12-13 -Y/+X Panel Voltage 39 Status Register
14-15 -X/+Z Panel Voltage 40 Cycle Counter
16-17 -Z/+Y Panel Voltage 41-42 Remaining active absolute capacity register
18-19 Solar Panels Boosts Output Voltage 43-44 Remaining standby absolute capacity register
20-21 Main Power Bus Voltage 45 Remaining active relative capacity register
22-23 Beacon-EPS Current 46 Remaining standby relative capacity register
24-25 MCU Internal Temperature 47-67 RTD1 - RTD7 Temperatures
26-27 Batteries Average Current 68 Energy Level

Back to Top

Minimal Data Packet

This packet contains only a small amount of the EPS data. It is sent to Beacon during normal software flow.

Position Variable Position Variable
0-1 -Y Panel Current 28-29 Batteries Monitor Temperature
2-3 +X Panel Current 30-31 Battery 1 Voltage
4-5 -X Panel Current 32-33 Battery 2 Voltage
6-7 +Z Panel Current 34-35 Batteries Current
8-9 -Z Panel Current 36-37 Batteries Accumulated Current
10-11 +Y Panel Current 38 Protection Register
12-13 -Y/+X Panel Voltage 39 Status Register
14-15 -X/+Z Panel Voltage 40 Cycle Counter
16-17 -Z/+Y Panel Voltage 41-42 Remaining active absolute capacity register
18-19 Solar Panels Boosts Output Voltage 43-44 Remaining standby absolute capacity register
20-21 Main Power Bus Voltage 45 Remaining active relative capacity register
22-23 Beacon-EPS Current 46 Remaining standby relative capacity register
24-25 MCU Internal Temperature 47-67 RTD1 - RTD7 Temperatures
26-27 Batteries Average Current 68 Energy Level

Back to Top

Debug Data Packet

This packet is sent via UART to debug pins. It is sent already decoded and with values separated by comma.

Position Variable Position Variable
1 -Y Panel Current 13 Vpanels Voltage
2 +X Panel Current 14 Vbus Voltage
3 -X Panel Current 15 Beacon/EPS Current
4 +Z Panel Current 16 RTD2 Temperature
5 -Z Panel Current 17 RTD6 Temperature
6 +Y Panel Current 18 Energy Level
7 -Y/+X Panel Voltage 19 Battery 1 Voltage
8 -X/+Z Panel Voltage 20 Battery 2 Voltage
9 -Z/+Y Panel Voltage 21 Batteries Current
10 -Y/+X Panel Power 22 Batteries Average Current
11 -X/+Z Panel Power 23 Batteries Accumulated Current
12 -Z/+Y Panel Power 24 Protection Register

Back to Top

Clone this wiki locally