This PR is to add information on how to use LA100-P to AMDS documentation.

I added;

  • the description of the burden register and current sensor gains with LA100-P, which has +/- 150 Aamp
  • the LA100-P to the BOM CSV file
  • the datasheet of LA100-P

@ngadiyar93, please review these changes above.

@elsevers
Copy link
Contributor

Thanks @noguchi-takahiro, I'll have you do a round of revision with @ngadiyar93. Then I am realizing that we'll need you to make these same changes here as well --> source is here.


### Current Sensor
LEM LA 55-P current sensor is selected for this design, as it is the only sensor available from LEM with an open aperture and PC pins that can measure +/-55A.
LEM LA 55-P and LA 100-P current sensors are selected for this design, as it is the only sensor available from LEM with an open aperture and PC pins that can measure +/-55A and +/-150A, respectively.
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@noguchi-takahiro this sentence as is isn't quite grammatically correct.
Can you improve it to say that Either LA-55P or LA 100-P can be used with this design based on the sensing range desired (and provide the sensing range as you are currently doing).

Also please include a note saying that LA-100P has a variant SP/13 which has a different gain that users must be careful about when ordering.

Copy link
Member

@ngadiyar93 ngadiyar93 left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@noguchi-takahiro Thank you for updating the document and the BOM.

I have a minor change request that I have indicated in-line. Please let me know once you have fixed it.

@noguchi-takahiro
Copy link
Author

Thanks, @ngadiyar93

I changed the sentences that you mentioned. And please review it and let me know of further improvements and requests.

@ngadiyar93 ngadiyar93 self-requested a review August 9, 2023 16:46
Copy link
Member

@ngadiyar93 ngadiyar93 left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@noguchi-takahiro Thank you for updating the document.
I have left you a couple of items which should be pretty quick to address.


### Current Sensor
LEM LA 55-P current sensor is selected for this design, as it is the only sensor available from LEM with an open aperture and PC pins that can measure +/-55A.
LEM LA 55-P or LA 100-P current sensors are selected and can be used for this design based on the sensing range desired. They are available from LEM with an open aperture and PC pins. LEM LA 55-P and LA 100-P can measure +/-55A and +/-150A, respectively. Note that the LA100 series also has these variants, LA100-P/SP13 and LA100-TP, which have different gains that users must be careful about when ordering.
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@noguchi-takahiro can you update this line as follows:
Based on the sensing range desired, the current measurement card can use either LA 55-P or LA 100-P from LEM. These sensors have an open aperture and PC pins. The LA 55-P can measure +/-55A while the LA 100-P can measure +/-150A.


### Current Sensor
LEM LA 55-P current sensor is selected for this design, as it is the only sensor available from LEM with an open aperture and PC pins that can measure +/-55A.
LEM LA 55-P or LA 100-P current sensors are selected and can be used for this design based on the sensing range desired. They are available from LEM with an open aperture and PC pins. LEM LA 55-P and LA 100-P can measure +/-55A and +/-150A, respectively. Note that the LA100 series also has these variants, LA100-P/SP13 and LA100-TP, which have different gains that users must be careful about when ordering.
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@noguchi-takahiro Can you add the Note about the LA 100 series variants in a separate line with the word "Note" in bold as follows (please refine the language to be better than what I am saying):

Note: The LA 100 series has three variants LA 100-P, LA 100-P/SP13, and LA 100-TP. The sensor gains of each of these variants are different, which has implications in the choice of the burden resistor. The rest of this document is specific to the LA 100-P variant.

The open aperture was a requirement as it allows for the range to be easily scaled down just by adding turns to the primary.
The LA 55-P is a closed loop compensated hall effect transducer that has an accuracy of +/-0.65% and linearity of <0.15% which is quite good compared to other sensors from LEM.
It has an excellent bandwidth of 200khz and a low impedance current output that is inherently more immune to noise than a high impedance voltage output.
The LA 55-P is a closed loop compensated hall effect transducers that has an accuracy of +/-0.65% and linearity of <0.15% which is quite good compared to other sensors from LEM. The LA 100-P has an accuracy of +/-0.45% and linearity of <0.15%.
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

transducers, please update to be transducer since it is singular.

@noguchi-takahiro
Copy link
Author

Thank you, @ngadiyar93. Please review it again.

We also need to address this below.

Thanks @noguchi-takahiro, I'll have you do a round of revision with @ngadiyar93. Then I am realizing that we'll need you to make these same changes here as well --> source is here.

@elsevers elsevers deleted the branch develop September 19, 2024 03:54
@elsevers elsevers closed this Sep 19, 2024
@npetersen2
Copy link

@elsevers this PR closed due to deleting its target branch. Do you still want this content to be merged?

@elsevers
Copy link
Contributor

Thanks @npetersen2. Good catch. I did not mean to close this PR.

@elsevers elsevers reopened this Sep 23, 2024
@elsevers elsevers self-requested a review as a code owner September 23, 2024 01:27
@elsevers elsevers changed the base branch from v2.0-staging to develop September 23, 2024 01:27