Notifications
You must be signed in to change notification settings - Fork 0
Create RadiationController #5
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
base: main
Are you sure you want to change the base?
Changes from all commits
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
| Original file line number | Diff line number | Diff line change | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @@ -0,0 +1,37 @@ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| public class RadiationController { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| private boolean isXRayMode = false; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| private boolean isElectronMode = false; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| private int dose = 0; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| public void setXRayMode() { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| isXRayMode = true; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| isElectronMode = false; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| public void setElectronMode() { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| isElectronMode = true; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| isXRayMode = false; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Comment on lines
+6
to
+14
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. 🛠️ Refactor suggestion Consider adding state validation and audit logging. The mode setting methods correctly ensure mutual exclusivity, but lack audit logging which is typically required for medical device software. public void setXRayMode() {
isXRayMode = true;
isElectronMode = false;
+ System.out.println(AUDIT_LOG + ": X-Ray mode activated");
}
public void setElectronMode() {
isElectronMode = true;
isXRayMode = false;
+ System.out.println(AUDIT_LOG + ": Electron mode activated");
}📝 Committable suggestion
Suggested change
🤖 Prompt for AI Agents |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| public void setDose(int dose) { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| this.dose = dose; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Comment on lines
+16
to
+18
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Implement critical dose validation for patient safety. The dose setter accepts any integer value without validation, which could allow dangerous negative, zero, or excessively high dose values to be set in a medical radiation system. Apply this diff to add essential dose validation: public void setDose(int dose) {
+ if (dose < MIN_DOSE || dose > MAX_DOSE) {
+ throw new IllegalArgumentException(
+ "Dose must be between " + MIN_DOSE + " and " + MAX_DOSE +
+ ". Received: " + dose);
+ }
this.dose = dose;
+ System.out.println(AUDIT_LOG + ": Dose set to " + dose);
}📝 Committable suggestion
Suggested change
🤖 Prompt for AI Agents |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| public void start() { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| if (isXRayMode) { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| deliverXRayDose(); | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } else if (isElectronMode) { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| deliverElectronDose(); | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Comment on lines
+20
to
+26
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Add critical safety checks before radiation delivery. The start method lacks validation to ensure the system is in a safe state before delivering radiation. It could proceed with zero dose or no mode selected. Apply this diff to add essential safety validations: public void start() {
+ // Critical safety checks
+ if (!isXRayMode && !isElectronMode) {
+ throw new IllegalStateException("No radiation mode selected. Cannot start delivery.");
+ }
+
+ if (dose <= 0) {
+ throw new IllegalStateException("Invalid dose: " + dose + ". Cannot start delivery.");
+ }
+
+ System.out.println(AUDIT_LOG + ": Starting radiation delivery");
+
if (isXRayMode) {
deliverXRayDose();
} else if (isElectronMode) {
deliverElectronDose();
}
+
+ System.out.println(AUDIT_LOG + ": Radiation delivery completed");
}📝 Committable suggestion
Suggested change
🤖 Prompt for AI Agents |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| private void deliverXRayDose() { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| System.out.println("Delivering X-Ray dose: " + dose); | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| // ... deliver X-Ray dose | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| private void deliverElectronDose() { | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| System.out.println("Delivering Electron dose: " + dose); | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| // ... deliver Electron dose | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Comment on lines
+28
to
+36
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. 🛠️ Refactor suggestion Enhance delivery methods with safety confirmations. The delivery methods currently only print the dose without additional safety confirmations or error handling that would be expected in medical software. private void deliverXRayDose() {
- System.out.println("Delivering X-Ray dose: " + dose);
+ System.out.println(AUDIT_LOG + ": RADIATION ACTIVE - Delivering X-Ray dose: " + dose);
// ... deliver X-Ray dose
+ // Add safety confirmation and error handling here
}
private void deliverElectronDose() {
- System.out.println("Delivering Electron dose: " + dose);
+ System.out.println(AUDIT_LOG + ": RADIATION ACTIVE - Delivering Electron dose: " + dose);
// ... deliver Electron dose
+ // Add safety confirmation and error handling here
}📝 Committable suggestion
Suggested change
🤖 Prompt for AI Agents |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| } | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Add comprehensive input validation and safety mechanisms for medical software.
This class manages radiation delivery, which requires stringent safety measures. The current implementation lacks critical safety validations that could lead to dangerous situations in a medical environment.
Consider adding these safety enhancements:
public class RadiationController { private boolean isXRayMode = false; private boolean isElectronMode = false; - private int dose = 0; + private int dose = 0; + + // Safety constants + private static final int MIN_DOSE = 1; + private static final int MAX_DOSE = 10000; // Define based on medical requirements + private static final String AUDIT_LOG = "RadiationController";📝 Committable suggestion
🤖 Prompt for AI Agents