Industrial Soil Sensor RS485

Industrial-Grade Soil Sensor: Measure multi-parameters of soil including Temperature, Moisture, pH, EC and Nitrogen, Phosphorus and Potassium (NPK). The output signal is RS485 and can be operated broad range of voltage from 5~30 VDC.

Soil Sensors Specifications

  • Operating Voltage: 5 ~ 30 VDC
  • Communication Protocol: RS485
  • Temperature
    • Measurement Range: -40°C ~ 80 °C
    • Measurement Accuracy: ±0.5 °C
  • Moisture Content
    • Measurement Range: 0 ~ 100 %
    • Measurement Accuracy: ±3 %
  • Electrical Conductivity (EC).
    • Measurement Range: 0 ~ 20000 uS/cm
    • Measurement Resolution: 1 uS/cm
  • pH
    • Measurement Range: 3 ~ 9
    • Measurement Resolution: 0.1
  • NPK
    • Measurement Range: 0 ~ 2999 mg/kg
    • Measurement Resolution: 1 mg/kg

RS485 Communication Details

  • Data Bits: 8-bit
  • Parity Bits: NO
  • Stop Bit: 1
  • Error Checking: CRC
  • Baud Rate: 2400, 4800 (default), 9600
  • Device Address: 0x01
  • Function Code: 0x03
  • Data Code: 16 bits

Change Device Address

The default device address is 0x01. Valid address range is 1 to 254. The address is stored in register 0x07D0 and can be changed using write function code 0x10.

  • Example: Change device address from 0x01 to 0x02 (11 Bytes): 01 10 07 D0 00 01 02 00 02 42 C1
Address Code Function Code Register Address Number of Registers Byte Count Data (New Address) CRC
0x01 0x10 0x07 0xD0 0x00 0x01 0x02 0x00 0x02 0x42 0xC1

Note: Power cycle the sensor after changing the device address for the new address to take effect.

Change Baud Rate

The baud rate is stored in register 0x07D1 and can be changed using write function code 0x10.

  • Baud Rate Values: 0x00 = 2400, 0x01 = 4800 (default), 0x02 = 9600

  • Example commands from device address 0x02:

Baud Rate Command
2400 02 10 07 D1 00 01 02 00 00 D6 21
4800 02 10 07 D1 00 01 02 00 01 17 E1
9600 02 10 07 D1 00 01 02 00 02 57 E0

Note: Power cycle the sensor after changing the baud rate for the new setting to take effect.

3-in-1 Soil Sensor Parameters

  • Request Frame (8 Bytes)
Address Code Function Code Start Address Register Length of Register CRC
0x01 0x03 0x00 0x00 0x00 0x03 0x05 0xCB

Note: The Address Code and CRC bytes will differ if the device address has been changed from the default (0x01).

  • Example of Response Frame (11 Bytes)
Address Code Function Code Byte Number Moisture Temperature EC CRC
0x01 0x03 0x06 0x01 0xEF 0x01 0x44 0x00 0x04 0xB5 0x59
  • Byte Response Example Calculation
    • Moisture Content = (0x01 * 256 + 0xEF) * 0.1 = 49.5 %
    • Temperature = (0x01 * 256 + 0x44) * 0.1 = 32.4 °C
    • EC = (0x00 * 256 + 0x04) = 4 uS/cm

4-in-1 Soil Sensor Parameters

  • Request Frame (8 Bytes)
Address Code Function Code Start Address Register Length of Register CRC
0x01 0x03 0x00 0x00 0x00 0x04 0x44 0x09

Note: The Address Code and CRC bytes will differ if the device address has been changed from the default (0x01).

  • Example of Response Frame (13 Bytes)
Address Code Function Code Byte Number Moisture Temperature EC pH CRC
0x01 0x03 0x08 0x02 0x62 0x01 0x67 0x00 0x06 0x00 0x37 0xC2 0x06
  • Byte Response Example Calculation
    • Moisture Content = (0x02 * 256 + 0x62) * 0.1 = 61.0 %
    • Temperature = (0x01 * 256 + 0x67) * 0.1 = 35.9 °C
    • EC = (0x00 * 256 + 0x06) = 6 uS/cm
    • pH = (0x00 * 256 + 0x37) * 0.1 = 5.5

7-in-1 Soil Sensor Parameters

  • Request Frame (8 Bytes)
Address Code Function Code Start Address Register Length of Register CRC
0x01 0x03 0x00 0x00 0x00 0x07 0x04 0x08

Note: The Address Code and CRC bytes will differ if the device address has been changed from the default (0x01).

  • Example of Response Frame (19 Bytes)
Address Code Function Code Byte Number Moisture Temperature EC pH Nitrogen (N) Phosphorus (P) Potassium (K) CRC
0x01 0x03 0x0E 0x01 0xE6 0x01 0x55 0x05 0xDC 0x01 0x34 0x00 0x20 0x00 0x25 0x00 0x30 0x04 0x08
  • Byte Response Example Calculation
    • Moisture Content = (0x01 * 256 + 0xE6) * 0.1 = 48.6 %
    • Temperature = (0x01 * 256 + 0x55) * 0.1 = 34.1 °C
    • EC = (0x05 * 256 + 0xDC) = 1500 uS/cm
    • pH = (0x01 * 256 + 0x34) * 0.1 = 3.08
    • N = (0x00 * 256 + 0x20) = 32 mg/kg
    • P = (0x00 * 256 + 0x25) = 37 mg/kg
    • K = (0x00 * 256 + 0x30) = 48 mg/kg