@HansOlsson HansOlsson commented Jul 19, 2017

Underlying issue: If the mass flow source has nPorts=0 (the default) the model is singular (since the mass-flow is given in some way and also zero since there is nothing connected). Note that the other fluid-boundary elements do not have this restriction, and flow-sources in other domains at least have the connector-elements.

In general this can be complicated to detect - but in this case we can just set a minimum for nPorts to document that the model requires nPorts>=1 (the actual value of nPorts should be indirectly set by connecting to the ports), and help tools test this model and detect when it is used incorrectly. That's what I did.

It might be that this modifier should be on the original declaration in PartialFlowSource instead, and/or that an assertion would be clearer.

@HansOlsson HansOlsson added L: Fluid Issue addresses Modelica.Fluid (excl. Dissipation) enhancement New feature or enhancement labels Jul 19, 2017
@beutlich beutlich requested review from casella and hubertus65 August 2, 2017 19:30
@beutlich beutlich added this to the MSL_next-MINOR-version milestone Sep 18, 2017
@beutlich
Copy link
Member

@casella Any comment on this?

@beutlich beutlich closed this Jan 21, 2018
@beutlich beutlich reopened this Jan 21, 2018
@beutlich beutlich removed the request for review from casella January 21, 2018 11:43
@beutlich beutlich modified the milestones: MSL3.2.3, never Jun 3, 2018
@HansOlsson HansOlsson deleted the ConnectBoundary branch April 8, 2020 16:24