Logger for the PIP Inverter series ( USB + RS232 version) + BMV Battery Monitor
- Voltronic Axpert, Mppsolar PIP, Voltacon, Effekta, and other branded Oems
- Victron Battery Monitor BMV700 and BMV702
- latest version 1.5.0 version Primavera 05/2017
- working on 32bit UBUNTU / MATE.
- working on Raspberry Pi2/Pi3 version
- logs data from BMV battery monitor to Emoncms
- does not work on Windows.
- sends data to Emoncms
Emoncms is an open-source web application for processing, logging and visualising energy, temperature and other environmental data and is part of the OpenEnergyMonitor project.
- sends data to PVOutput.
PVOutput is a free service for sharing and comparing PV output data.
- copy file "solpiplog.rules" to your "/etc/udev/rules.d" directory. That way you dont have to excecute it as root
- from your terminal window, inside the folder where the file is sudo cp solpiplog.rules /etc/udev/rules.d
- unplug usb cable and replug
- make solpiplog executable with
- sudo chmod +x solpiplog or
- change it with graphical interface inside of Ubuntu / Mate. Right click on file - properties - permissions tab - tick execute allow excecuting file as program
- problably you dont even need to do it, if i dont forget to make it executable :)
- create an account on Emoncms or install Emoncms on your own server.
- optional: create an account on PVOutput.
- configure SolPipLog with your Emoncms API-Key
- optional configure SolPipLog with your PVOutput SystemID and API-Key.
- choose autoload config and start and press on Save ( if you restart SolPipLog it loads the config file and runs. )
Following values are sent to Emoncms and displayed as Node 30 with Key from 1-20 and 30-35
-
1 = AC_IN_V
-
2 = AC_IN_HZ
-
3 = AC_OUT_V
-
4 = AC_OUT_HZ
-
5 = AC_OUT_VA
-
6 = AC_OUT_W
-
7 = AC_OUT_LOAD_PERCENT
-
8 = BUS_V
-
9 = BATT_V
-
10 = BATT_CHRG
-
11 = BATT_CAPACITY_PERCENT
-
12 = HEATSINK_TEMP
-
13 = PV_I_BATT
-
14 = PV_V
-
15 = BATT_V_SCC
-
16 = BATT_DISCHRG_I
-
17 = PV Charging Power
-
18 = Line Mode ( 0 or 1 ) Link Led Widget for visualization
-
19 = Battery Mode ( 0 or 1 ) Link Led Widget for visualization
-
20 = Fault Mode ( 0 or 1 ) Link Led Widget for visualization
-
30 = Year for displaying lastest update
-
31 = Month
-
32 = Day
-
33 = Hour
-
34 = Minute
-
35 = Second
New since v 1.4.9 support for Inverter with two/three MPPT displayed as Node 31 with following Keys:
-
1 = PV2 current A
-
2 = PV2 volt V
-
3 = batt volt scc2 V
-
4 = PV power2 W
-
5 = device status
-
6 = AC charge current A
-
7 = AC charge power W
-
8 = PV3 current A
-
9 = PV3 voltage V
-
10 = batt volt scc3 V
-
11 = PV power3 W
-
12 = PV total W
-
30 = Year for displaying lastest update
-
31 = Month
-
32 = Day
-
33 = Hour
-
34 = Minute
-
35 = Second
BMV Battery Monitor displayed as Node 20 with following Keys:
- 1 = Battery voltage mV
- 2 = Battery current mA
- 3 = Instantaneous Power W
- 4 = Consumed amp Hours mAh
- 5 = State-of-Charge
- 6 = Time-To-Go in minutes
- 8 = Alarm status (ON/OFF) one for ON and zero for OFF
- 10 = Auxiliary (starter) voltage ## only with BMV-702
- 25 = Relay status (ON/OFF)
Following values are sent to PVOutput
- AC_OUT_V
- AC_OUT_W
- PV Charging Power
follow on http://www.photovoltaikforum.com/datenlogger-f5/usb-datenlogger-fuer-pip-serie-solpiplog-t114101.html raspberry image available. image based on RASPBIAN JESSIE WITH PIXEL, SAMBA installed ( folder Downloads visible on local network ), RealVNC installed, username and password are default ones from Jessie image.
-
1.5.0 * Primavera version
- support for Inverter with 2 MPPT
- logs aditional parameter for BMV702
- Sends UDP datagramm to a Server / for example to a Loxone Smart Home server
- autoload config and Start possible.
- bug crc errors solved
- solved timeout on 2MPPT versions solved
-
1.4.9a* rik_man UDP version
-
1.4.9 * tealc_hr internal forum release
-
1.4.8 * 03/2017 new change BULK and FLOAT
-
1.4.7 * Vollkorn changed how to Switch to UTI/SOL.
-
1.4.6 * BennyHH BMV logging without PIP online
-
1.4.5 * agenturrene v4 change charger priority
-
1.4.4 * agenturrene v3 switching SOC error
-
1.4.3 * agenturrene v2 faster bmv detection
-
1.4.2 * agenturrene v1 two MPPT version
-
1.4.1 * 11/2016 RS232 public release change on SOC activated. Changes inverter to UTI or SBU based on SOC
-
1.4.0 * Vollkorn release RS232 support for Inverter bugfixes, layout changed.
-
1.3.1 * BennyHH Soc version internal release
-
1.3.0 * 10/2016 NEW BMV Battery Monitor log parameter send to EmonCMS on Node 20
- Key 1 : Battery voltage mV
- Key 2 : Battery current mA
- Key 3 : Instantaneous Power W
- Key 4 : Consumed Amp Hours mAh
- Key 5 : State-of-Charge
- Key 6 : Time-to-go in minutes
- Key 8 : Alarm status ON/OFF
- Key 25: Relay status ON/OFF
-
1.2.6 * BennyHH v3 internal test
- new parameter 30 : Year
- new parameter 31 : Month
- new parameter 32 : Day
- new parameter 33 : Hour
- new parameter 34 : Minute
- new parameter 35 : Seconds
-
1.2.5 * BennyHH v2 internal test
- Added parameter 18 Line Mode
- Added parameter 19 Battery Mode
- Added parameter 20 Fault Mode
- add detection if internet connection available
-
1.2.4 -* bug timer overflow
- changes on workflow for slow machines
- rewritten parser
- cosmetic changes
- raspberry 2 version adaptation
- a lot of bugs removed
-
1.2.3.alpha - BennyHH version
-
1.2.2 - * bug timeout problems on slow machines increased to 5 seconds
- log screen . showing all errors.
-
1.2.1 - removed change by watt ( debug version )
- updated logo
- bug* Connect button without focus after clicking manual Disconnect
-
1.2 - fist public release