31 changes: 31 additions & 0 deletions internal/processor/adaptive.go
Original file line number Diff line number Diff line change
Expand Up @@ -225,6 +225,15 @@ const (
la2aKurtosisLowPeak = 5.0 // Below: flat spectrum, firmer ratio
la2aDynamicRangeWide = 35.0 // dB - above: add ratio boost

// LA-2A hot input protection
// When input true peak >= -1 dBTP, the signal is already loud enough that
// aggressive compression crushes dynamics unnecessarily. The downstream
// limiter handles peak control, so the compressor can afford to be gentler.
la2aHotInputTPThreshold = -1.0 // dBTP: above this, start backing off
la2aHotInputTPSevere = -0.5 // dBTP: above this, maximum backoff
la2aHotInputRatioReduction = 1.0 // Maximum ratio reduction (e.g. 3.5 → 2.5)
la2aHotInputHeadroomReduction = 5.0 // Maximum headroom reduction in dB

// LA-2A Threshold: Relative to peak level (like Peak Reduction knob)
// LA-2A's threshold is effectively signal-relative
// Headroom from peak level determines compression depth
Expand Down Expand Up @@ -1405,6 +1414,17 @@ func tuneLA2ARatio(config *FilterChainConfig, measurements *AudioMeasurements) {
ratio += la2aRatioDynamicBoost
}

// Hot input protection: back off ratio when true peak is high.
// The limiter downstream handles peak control, so the compressor
// can afford to be gentler on already-loud material.
if measurements.InputTP >= la2aHotInputTPThreshold {
severity := (measurements.InputTP - la2aHotInputTPThreshold) /
(la2aHotInputTPSevere - la2aHotInputTPThreshold)
severity = clamp(severity, 0.0, 1.0)
severity = math.Sqrt(severity)
ratio -= la2aHotInputRatioReduction * severity
}

// Clamp to reasonable range
config.LA2ARatio = clamp(ratio, 2.0, 5.0)
}
Expand Down Expand Up @@ -1434,6 +1454,17 @@ func tuneLA2AThreshold(config *FilterChainConfig, measurements *AudioMeasurement
headroom = la2aThresholdHeadroomLight
}

// Hot input protection: reduce headroom (raise threshold) for loud inputs.
// When peaks are already near 0 dBTP, less compression depth is needed
// because the limiter downstream handles peak control.
if measurements.InputTP >= la2aHotInputTPThreshold {
severity := (measurements.InputTP - la2aHotInputTPThreshold) /
(la2aHotInputTPSevere - la2aHotInputTPThreshold)
severity = clamp(severity, 0.0, 1.0)
severity = math.Sqrt(severity)
headroom -= la2aHotInputHeadroomReduction * severity
}

// Calculate threshold relative to peak level
// threshold = peak - headroom
// e.g., peak -5dB with 15dB headroom → threshold -20dB
Expand Down