Modern web interface for configuring and monitoring TOMPD-63 smart breakers.
-
Real-time Monitoring
- Voltage, current, and power measurements
- Leakage current detection
- Total energy consumption
- Fault status with detailed error messages
-
Protection Settings
- Leakage current protection (10-99mA)
- Overvoltage protection (110-300V)
- Undervoltage protection (85-220V)
- Overcurrent protection (1-63A)
- Configurable reaction time (1-30s)
- Configurable recovery time (1-500s)
-
Prepayment Mode
- Energy balance tracking
- Energy top-up functionality
- Automatic cutoff when balance depleted
-
Main Controls
- Remote relay on/off
- Energy counter reset
- Prepayment mode toggle
- TypeScript
- Vite
- Native Web Components
- UART communication via OpenBK7231T firmware
# Install dependencies
npm install
# Run development server
npm run dev
# Build for production
npm run build
# Create distribution archive
npm run archiveThe UI communicates with the breaker via UART using the Tuya MCU protocol:
- Message Format:
55 AA 00 06 [length] [dpId] [type] [payload_length] [payload] [checksum] - DpIDs: Device-specific data point identifiers for different settings
- Data Types: BOOL (0x01), INT (0x02), RAW (0x00)
Create a .env file in the project root to configure the device URL for development:
# .env
VITE_DEVICE_BASE_URL=http://192.168.0.178If not set, the app will use window.location.origin (the current page's origin). In production, when hosted on the device itself, no configuration is needed as it will automatically connect to the device serving the UI.
Inspired by discussions and contributions from the elektroda.com forum.