Control and monitor your HomeWizard Energy devices directly from your Homey smart home hub.
- Enable Local API - Open the official HomeWizard Energy app and enable "Local API" for your devices you like to add
- Add Homewizard Unit - First add your main Homewizard unit in Homey
- Add Devices - Then add related/connected components from Homewizard to your Homey (Heatlink, Energylink, Thermometers etc)
- P1 Meter Support - Monitor energy consumption in real-time (API v1 & v2)
- Smart Sockets - Control and monitor individual devices
- Battery Management - Track and control home battery systems
- Solar Integration - Monitor solar production and consumption
- Battery Policy Driver - Automated battery management based on dynamic tariffs or peak shaving
- Power Quality Monitoring - Trigger cards for voltage sags, swells, power failures, and restoration events
- Baseload Detection - Identify standby power consumption (sluipverbruik)
- Learning Engine - AI-powered pattern recognition for optimized battery charging
- Cloud API Support - Connect P1 meters and water meters via HomeWizard cloud
- P1 Energy Meters (API v1 & v2, including cloud-connected)
- Energy Sockets
- Plugin Battery
- SDM230 & SDM630 kWh Meters (3-phase, industrial grade)
- Water Meters (local & cloud)
- Legacy Devices (thermometer, heatlink, rainmeter, windmeter, sensors)
NEW in v3.13.14: Intelligent battery management system that:
- Responds to dynamic electricity tariffs
- Implements peak shaving strategies
- Learns consumption patterns over time
- Adjusts PV production estimates based on historical accuracy
- Provides confidence scoring for policy decisions
Note: Cloud-based features depend on internet connectivity and HomeWizard Energy platform availability. During maintenance or outages, you may experience errors or incorrect data.
- Discharge SoC projection now consumption-aware -
zero_discharge_onlykeeps grid at ~0W by matching discharge to actual house consumption (variable 0–800W), not fixed max discharge power. Planning chart SoC curve now reflects real depletion speed based on learned consumption per slot - Discharge floor consistent between DP and display - Optimizer now enforces
min_discharge_priceas a hard constraint in backward induction; eliminates the bug where planning showed "standby" but SoC dropped (DP had internally discharged below the threshold) - Opportunistic discharge in dynamic mode - When
respect_minmaxis disabled, the DP usesopportunistic_discharge_floor(default €0.20) instead ofmin_discharge_price, consistent with the policy engine's opportunistic logic. Planning display matches - Pre-peak urgent charging - When an expensive hour is ≤30 min away and SoC is below target, policy switches to
to_fulleven when PV is producing (≥400W), ensuring the battery fills in time
- Lat/lon location fields - Weather location now uses separate latitude/longitude number fields instead of a city name text field. Existing city names are automatically migrated on first startup
- Forecast blending - New weather fetch is blended with the previous cache (α=0.6) to smooth sudden Open-Meteo model-run jumps; prevents PV forecast from jumping between runs
- Weather refresh interval - Cache refresh now uses the existing
weather_update_intervalsetting (default 3h, min 1h) instead of a hardcoded 3-hour interval
- PV overschot score rebalanced - Score reduced from +1000 to +250 to keep all scores in the readable 20–300 range; still dominates preserve but no longer produces scores like 1170
battery_group_charge_modecapability missing - Self-healing guard added: if the capability is absent when a battery event arrives, it is re-added beforesetCapabilityValue()is called, preventing repeated "Invalid Capability" errors- BaseloadMonitor false oscillation -
_detectOscillation()now trims 1 outlier from each end before computing the range; a single bad sample from battery mode-transition measurement lag no longer invalidates an otherwise clean night - BaseloadMonitor energy_v2 - Battery power sourced from
plugin_battery(accurate) instead of the P1payload.power_wfield (unreliable when firmware doesn't report battery state) - Settings crash on PV/weather change -
homey.settings.unset()is synchronous; removed erroneous.catch()call that crashed when settings were changed
- Single source of truth - Planning view now reads directly from the optimizer schedule; no duplicate policy logic in the frontend
- Accurate SoC projection - Forward pass now reflects PV-assisted charging during preserve slots (firmware runs zero_charge_only when PV is available)
- Solar yield learning - Per-slot yield factors (W per W/m²) learned from actual PV measurements, absorbing panel capacity, orientation, PR and shading into one number. Approach inspired by de Gruijter's app
- Weekend/weekday consumption patterns - Learning engine distinguishes weekday vs weekend consumption; falls back to group average until enough per-day samples accumulate
- Consumption-aware planning - Optimizer uses learned consumption forecasts per slot; discharge offsetting local consumption is valued at full retail price vs 30% for export
- Battery cycle cost - Configurable degradation cost (€/kWh discharged); optimizer only cycles the battery when the price spread exceeds the cycle cost, preventing unprofitable small arbitrage rounds
- 15-min price granularity - Policy decisions now use the actual 15-minute spot price instead of the hourly average, enabling more precise charge/discharge timing during short price dips or peaks
- Optimizer on 15-min slots - The 24h dynamic-programming scheduler now plans across 96 slots (15-min) instead of 24 hourly slots, making it possible to exploit short cheap windows (e.g. wind surplus at night)
- Reasons match the winning mode - Decision reasons are now filtered to only show why the actual recommendation was made; conflicting reasons from other modes no longer appear
- Mapping explanation - When scoring favours charging but conditions prevent it (price above ceiling, no PV), a prominent notice now explains the gap: "Laden wint (score 140) maar prijs €0.26 > max laadprijs €0.14 → Standby: wacht op betere conditie"
- Battery very low reason - SoC between 1–10% now correctly shows "Batterij erg laag — laden aanbevolen" instead of "normaal bereik"
- Zero mode threshold - Explainability engine now mirrors policy engine exactly: respects
min_soc = 0without a hardcoded 1% floor
- Weather forecast timezone - Fixed 1-hour offset caused by
timezone: auto+ appending Z; now usestimezone: UTC - Sunshine duration ensemble - Fixed all-zero sunshine when using multi-model Open-Meteo requests (
models=parameter causes model-specific key names likesunshine_duration_ecmwf_ifs04; plain key absent) - Planning SoC projection - Fixed all hours showing standby due to early return
if (soc < minSoc) return 'standby'in planning display; radiation-based PV formula corrected (pvCapW × radiation/1000instead ofmaxChgW × factor) - ZERO MODE threshold - Policy engine and explainability now both respect user's
min_socsetting; removed hardcoded 5% / 1% floors
- 36-hour forecast horizon - Weather forecaster extended from 24h to 36h to always cover tonight + full tomorrow even when run in the evening
- SunMultiSource removed - Replaced with WeatherForecaster ensemble (3-model average); next-4h radiation used for PV estimation
- OptimizationEngine - New dynamic-programming scheduler that computes the optimal charge/discharge schedule across the full 24-hour price horizon. The policy engine now has genuine lookahead instead of relying purely on heuristics, improving decisions around when to charge cheap and discharge at peak.
- Explainability color coding - Policy decision reasons now show color-coded tags with relative weights, making it easier to understand what drove the recommendation.
- Planning solar charge - Fixed planning page incorrectly showing solar charge in the evening/night hours
- Incorrect PV charge at night - Fixed battery policy charging from grid during nighttime when PV flag was incorrectly set
- WebSocket throttle configurable -
energy_v2WebSocket measurement throttle is now adjustable in device settings (default 2s) - WebSocket logging - Improved WebSocket connection tracking and diagnostics in the settings page
- Baseload Negative Values - Fixed
BaseloadMonitor._fallback()including negative power samples in bottom-10% calculation, which caused the baseload (sluipverbruik) to report negative values; now filters top >= 0 && p < 1000 W(consistent with_computeSmartBaseload) - Baseload Battery Correction - Fixed
updatePower()only correcting for battery discharge (batteryPower < 0) but not for charging; now applieshouseholdPower = gridPower − batteryPowerfor both directions; result clamped to 0 to prevent negative household consumption from rounding/timing mismatches - RTE Learning — Counter Reset Bug - Fixed efficiency estimator resetting both charge and discharge counters when measured RTE < 0.50; a low ratio simply means the cycle is not complete yet (not enough discharge accumulated relative to charge); counters now preserved and continue accumulating; only reset on confirmed measurement error (RTE > 0.85) or stale counters (> 10 kWh either side)
- RTE Learning — SoC Null Guard - Fixed
soc <= 5orphan-clear guard inEfficiencyEstimatorfiring on every charge start becausenull <= 5istruein JavaScript; guard now requirestypeof soc === 'number' - RTE Learning — Wrong SoC Source - Fixed
battery-policy/device.jsreadingmeasure_batterycapability (does not exist on the policy device → alwaysnull) instead of thesocvariable already resolved frombattery_group_average_socon the P1 device - Battery Policy bugs - Fixed Recommended mode text to active mode, leftover battery SoC in morning to discharge. Fix for
to_fullwhen PV is not enough to charge battery but the market prices are at their lowest (zero_change_only vs to_full) - Ratelimit on flowcards in energy (apiv2) - Ratelimit to avoid action flowcard to execute every second crippling the application and make it cpu/memory crash
- Energy socket connectivity - Improve connectivity when there is poor wifi (10s timeouts, was 5s) and retry logic
- WebSocket slow_handler threshold raised from 100 ms to 250 ms to better reflect ARM CPU reality on Homey; journal entries throttled to once per handler per 5 minutes to prevent log noise
- WebSocket preflight_fail journal events throttled to once per 10 minutes via
_journalThrottled(); log output still emitted on every failure for debugging - Settings page copy button —
navigator.clipboard.writeText()silently fails inside Homey's sandboxed iframe; now always usestextarea + execCommand('copy')as primary path; if that also fails a selectable textarea is shown as manual fallback
- Active Mode Capability - New
active_modecapability shows the battery mode actually active on the hardware, which may differ fromrecommended_modewhen confidence is below threshold, auto-apply is off, or a manual override is active - New Policy Modes - Added
Fixed PricingandDynamic Pricing (V2)options to the policy mode picker - Global Error Handlers - App now catches unhandled promise rejections, uncaught exceptions, and Node.js process warnings (MaxListenersExceededWarning etc.) for better crash diagnostics
- Coverage Ratio Calculation - Fixed inverted battery coverage ratio: a 1751 W load with 800 W max now correctly reports 46% coverage instead of 100%
- Multi-Unit Battery Power - Max discharge/charge fallback now scales with battery group size (2.7 kWh/unit × 800 W/unit) instead of hardcoding 800 W regardless of how many units are installed
- PV Virtual Grid Calculation - Fixed virtual grid calculation: battery charging power is now subtracted (not added) to correctly show true export potential when evaluating PV decisions
- WebSocket Null Guards - Fixed crashes when
ws._eventsis accessed after the socket is already cleaned up;removeAllListenersand event dispatch now guard against nullwsreference - Cost Model Reset - Battery cost model now resets at or below
min_soceven when firmware cuts discharge power to 0 W (no longer waits forisDischargingto be true) - Sensor/History Overflow -
LearningEnginenow uses exponential moving average (alpha=0.01) after 100 samples per slot, preventingsumandcountfrom growing unboundedly over years
- WebSocket Throttle - Measurements now processed immediately on receive with a 2 s throttle, replacing the previous fixed polling interval; system/battery topics reduced to 30 s (was 10 s)
- energy_v2 Tiered Updates - Capability updates split into realtime / 10 s / 30 s / 60 s tiers; voltage, current, and frequency no longer updated on every WebSocket message
- energy_v2 Battery Group - Battery group interval reduced from 10 s to 60 s
- energy_v2 Flow Triggers -
energy_import_kwhflow trigger rate-limited to 60 s (was 5 s), preventing 12 triggers/min per device - energy_socket Polling - Minimum poll interval raised to 30 s (was 2 s); startup offset staggered 5–35 s; TCP keep-alive extended to 35 s to match interval
- plugin_battery Startup Stagger - First poll staggered 0–30 s per device to prevent 3 simultaneous TLS handshakes at startup
- plugin_battery Battery Group - Battery group interval reduced from 10 s to 60 s
- plugin_battery Capability Batching - All capability updates in
_handleMeasurementare now batched withPromise.allSettled(non-blocking) instead of sequentialawait - Baseload Throttle -
BaseloadMonitor._processNightSamplestores at most 1 sample per 30 s;_detectNearZeroLongis now time-based instead of sample-count-based; night history downsampled to 30 s resolution on save - Battery Policy P1 Polling - P1 capability polling interval increased from 5 s to 15 s
- WebSocket internals refactored; debug and runtime statistics are now surfaced in the settings page for improved diagnostics
onUninit/onDeletedsplit across all drivers (energy_v2,energy_socket,plugin_battery,cloud_p1,battery-policy): timers/intervals cleaned up on both app stops and explicit device deletion; baseload deregistration and settings wipe only on deletion__deletedguard added toonPoll,_fallbackPoll,_updateBatteryGroup, and_handleMeasurementto prevent errors after uninit- PV state detection uses separate hysteresis thresholds for ON (−200 W) vs OFF (−150 W) to prevent bouncing; grid range widened to −150…+250 W when already in PV state
active_modeupdated after every policy run to reflect the actualbattery_group_charge_modecapability value from the P1 device;battery_policy_state.currentModepatched to match for accurate SoC projection- RTE learning bounds enforced (50–85%); values outside this range fall back to the configured setting and trigger an estimator reset; learning threshold lowered to 1.0 kWh per side (was 2.5 kWh) for faster convergence
EfficiencyEstimator.reset(eff)method added- Explainability engine: soc=0 reason now mirrors policy-engine export-wins analysis; arbitrage reason now shows when price is above break-even but blocked by
min_discharge_price; PV surplus reason mirrors PV OVERSCHOT opportunity-cost logic - Coverage ratio formula corrected to
min(maxDischarge / load, 1.0)inPolicyEngine,_applyPeakShavingRules, andExplainabilityEngine - Battery group max power fallback derived from
battery_group_total_capacity_kwhin device, policy engine, and explainability engine
- Battery Policy PV Detection - Fixed incorrect grid charging during active PV production
- WebSocket Stability - Improved reconnection logic and error handling for energy_v2 and plugin_battery drivers
- Policy engine mapping logic now respects sticky PV detection state set by
_applyPVReality() - PV detection includes
pvEstimateas additional indicator alongside grid export and battery power - Improved logging shows virtual grid power breakdown for better debugging
- Enhanced WebSocket connection resilience during network fluctuations
- Manual IP Override - Repair flow for devices when mDNS discovery fails (VLAN/UniFi/mesh Wi-Fi issues)
- Battery-Aware Baseload - Excludes battery discharge from grid power for accurate standby consumption
- Smart Filtering - Automatically filters EV charging and heat pump cycles from baseload calculation
- Dynamic Sunrise/Sunset - Battery discharge windows adapt to seasonal changes (sunset-based timing)
- Weather-Aware Discharge - Battery policy uses tomorrow's solar forecast for intelligent discharge decisions
- Monthly Cost Display - Settings page shows estimated baseload costs with real-time pricing
- Discovery error messages now guide users with mDNS troubleshooting steps (EN/NL)
- Baseload monitor uses median of lowest 50% samples for robust calculation
- Settings page displays visual ML score progress bars
- Explainability engine shows weather-aware reasoning with dynamic time windows
- General UI and logging refinements for clarity and consistency
- Pre charge only when it's profitable
- Planning update when min max prices are changed by user affecting decisions
- Manual IP support for both P1 Meter (v1) and P1 Meter (apiv2) drivers
- Discovery events properly ignored when manual IP is configured
- Fixed €0.25 estimate for baseload costs to prevent API overload from 15k users
- Internal refactoring improves stability, caching behavior, and driver initialization
- Battery Policy driver with ML-based charging optimization
- Trigger cards for energy grid errors, voltage swells, voltage sags, and restoration events
- Learning engine for consumption patterns and PV accuracy tracking
- Plugin Battery state of charge icon for dashboard
- Homewizard Legacy Device updates (CSS, flow and language) - thanks smarthomesvan
- P1 meters can now connect via HomeWizard cloud API (thanks to Sven Serlier's research)
- Watermeter cloud support (4x daily updates via hwenergy)
- P1 (apiv2) tariff trigger improvements
- Fixed capability_already_exists error (cloud_p1)
Click to expand complete version history
- Plugin battery charge mode selectable from UI
- Energy (apiv2) guard for add/remove "battery_group_charge_mode"
- P1 tuning TIMEOUT & Unreachable
- Removed pollingActive (unwanted side effect)
- Baseload ignore return power (compensate battery return to grid datapoints)
- Plugin Battery LED brightness adjustment (user request)
- Bug fix: Battery Group (SoC missed when there are fetch errors)
- Bug fix: Polling deadlock fix for (energy, energy_socket, SDM230, SDM630, watermeter)
- Energy socket setAvailable fix
- Bugfix: _cacheSet undefined
(Websocket & caching)
- Optimized external meters hash calculation (eliminates array.map() garbage collection pressure)
- Battery group settings now cached with 60-second refresh
Baseload / sluipverbruik
- Detection algorithms now run every 30 seconds instead of on every power sample
- Eliminates expensive array scans during night hours
v3.11.9
- P1 energy modified to modular
- P1 energy_v2 modified to modular
- Heatlink additional code check on set target_temperature
- P1, changed order of processing, eletric first then gas/water
- P1 missed call in onPoll interval to reset daily calculation
- Bugfix: P1 (apiv2) polling mode - Charge mode fixes
- Bugfix: Group Battery State of Charge (increased timestamp check)
- Realtime pull from all batteries as fallback Battery Group State
v3.10.13
- Updated plugin battery mode names
- Added device name to debug messages
- SDM630 added per phase kwh meter tracking + daily kwh meter (estimate)
- More gas fix reset at night time (apiv1 and apiv2)
- Bugfix: incorrect daily reset during day of gas usage
- Bugfix: Energylink (watermeter) and Thermometer (battery) NOTE: This is an estimate based on polling interval. If bad wifi or Homey can't reach the SDM630 the measured value will be lower than the actual data.
v3.10.7
- Bugfix: Homewizard Legacy fetch (tab was empty, no entries while there were errors in the log)
- Remove fetchQueue feature in favor of capture debug information in the app settings page
- Watermeter daily usage added
- Bugfix: Device Fetch Debug wasn't updating only showed "Loading..."
- Bugfix: Circular Reference "device"
- Bugfix: SDM230(p1mode) - updateCapability missed
- Finetune debug log (ignore message circuit_open)
- Energy_socket finetune, added a device queue as a replacement for the earlier centralized fetchQueue
- Homewizard adaptive polling + tuning timeouts
- Cleanup device drivers with overcomplicated checks that ended up with polling deadlocks
- SDM230(p1mode) - Extra code handling for TIMEOUT issues
- Daily gas usage reset improvement (nighttime sometimes misses when there is no gas value received)
v3.9.29
- Wsmanager optimize
- Homewizard legacy custom polling
- Driver.js (apiv2) log fix (this.log undefined)
- Thermometer rollback (name index matching doesnt work as expected)
- Homewizard legacy -> node-fetch and not the fetchQueue utility (bad user experience feedback)
- Baseload (sluipverbruik) improvement (fridge/freezer should not be flagged as invalid )
- Homewizard app setting page with log or debug information for discovery, fetch failures, websocket problems and baseload samples
- Bugfix: Homewizard.poll (legacy unit)
- Homewizard Legacy fetch debug added to same section under Application settings
- Heatlink Legacy improvement
- Homewizard Legacy Preset improvement (UI picker in Homey app)
- Using external gas meter (timestamp X) instead of administrative meter
- Thermometer trigger and condition cards for no response for X hours.
- Improvement fetchQueue (protect against high cpu warning for devices on 1s polling)
v3.9.20
- New Plugin Battery mode support (zero_charge_only & zero_discharge_only)
- Optional gas checkbox (default enabled) for P1 (apiv1 and apiv2). (User request)
- Added 15min power datapoint for Belgium (average_power_15m_w) P1(apiv2) (user request)
- Plugin Battery - Bugfix setMode for to_full (PUT)
- Updated SDM230_v2 and SDM630_v2 drivers
- Bugfix - Updated P1apiv2 check-battery-mode condition card
- Backward compatibilty fix for the new battery mode applied to older P1 firmware.
- Bugfix - Websocket payload battery mode adjustment
- Fixed: rare crash when _handleBatteries() ran after a device was deleted, causing Not Found: Device with ID … errors during setStoreValue.
- Phase overload notification setting added and a limiter to avoid notification flooding
- New Feature: Baseload (sluipverbruik) detection (experimental)
- Bugfix: energy_socket connection_error capability fix
- Bugfix: energy_v2 (handleBatteries) - device_not_found crash
- Bugfix: trigger cards for SDM230_v2
- APIv2 change pairing: Modified the username that is used during pair made it unique per homey
- Bugfix: APIv2 pairing -> local/homey_xxxxxx
- Bugfix: SDM630v2 trigger cards removed (obsolete as these are default Homey)
- Finetune: P1(apiv2) websocket + polling, capability updates
- Finetune: energy_sockets (fetch / timeout) centralized
- Refractor code update for P1apiv1, SDM230, SDM630, watermeter
- Customizable phase overload warning + reset
- Phase 1 /3 fix for P1(apiv1) after refractor code update
- Bugfix: Fallback url for SDM230v2 and P1apiv2 (mDNS fail workaround)
- Bugfix: pairing problem "Cannot read properties of undefined (reading 'log')
- Homewizard legacy, clear some old callback methods
- Finetune async/await updates
v3.8.22
- Finetune energy_v2 updates primary values are updated instant, other lesser values once every 10s
- Additional watchdog code to reconnect energy_v2 and plugin_battery upon firmware up/downgrades
- Websocket finetuning (energy_v2 and plugin battery)
- Centralized fetch queue for all fetch calls to spread all queries
- Removed interval check in onPoll loop
- Restore custom polling sockets (got removed by accident rollback)
v3.8.18
- Bugfix: Failed to recreate agent: TypeError: Assignment to constant variable (energy)
- Adjustment to async/await code several drivers
v3.8.16
- Updated APIv2 to add more text upon fetch failed
- Websocket based battery mode settings added (both condition and action)
- Websocket heartbeat (30s) to keep battery mode updated (workaround as battery mode is the only realtime update when it changes)
- P1 & EnergySocket driver (apiv1) http agent tuning (ETIMEOUT and ECONNRESET)
v3.8.13
- Extra error handling (updateCapability) based on received crashreports
- Bugfix: ReferenceError: err is not defined (energy_socket)
v3.8.11
- Rollback energy dongle code from earlier version v3.7.0
- Strange SD630 problem on older Homey's
- Extra verbose logging in urls to expose mDNS problems for older Homeys (url)
v3.8.8
- After attempting conditional fetch, roll back to node-fetch until 12.9.x releases (Homey Pro 2016 - 2019)
- Bugfix: SDM230-p1mode - error during initialization
v3.7.9
- Extra check upon websocket creation to avoid crashes
- Plugin battery catch all error (unhandled exception)
- Additional checking and error handling on bad wifi connections (websocket based)
- (fix) Error: WebSocket is not open: readyState 0 (CONNECTING)
- Fetch was not defined for fetchWithTimeout function
- Missed net_frequency update, also made it 3 decimals
- Capability update fix (avoid removal check)
v3.7.1
- Trigger card for battery SoC Drift (triggers on expected vs actual State-of-charge)
- Trigger card for battery error (based on energy returned to grid while battery group should be charging)
- Trigger card for battery netfrequency out of range
- Icon update for various capabilities
- Battery group details added to P1apiv2. (Charging state)
- Realtime data for P1 (apiv2) via Websocket
- Realtime data for Plugin Battery via Websocket
- Bugfixes/crashes on P1 (apiv2) - no gas data on first poll / ignore
- Websocket reconnect code for covering wifi disconnect & terminate issues
- Plugin Battery group fix (tracking combined set of batteries) - bugfix / Refenece error
- Netfrequency capability added for Plugin Battery
- Homewizard Legacy - code rollback (pairing problems after improvements)
- P1 (apiv2) - Added checkbox setting to fallback to polling if websocket is to heavy for Homey device
v3.6.77
- Custom polling-interval option made for Homewizard Legacy unit (default 20s, when adjusted restart app to active it) To adjust setting check the main unit advanced settings
- Energy sockets with poor wifi connection will have 3 attempts now
- Fallback url for P1 mode SDM230 / SDM630
v3.6.75
- Thermometer (Homewizard Legacy) - full code refractoring
- Homewizard Legacy doesnt support keep-alive, changed back to normal fetch / retry
- Finetune code keepAlive for other devices 10s
- Bugfix: number_of_phases setting incorrectly updated
- Added verbose mDNS discovery results for troubleshooting
v3.6.73
- More try/catch code to avoid any crashes on Homewizard Legacy main unit getStatus fail (Device not found)
- Fine tune "estimated kwh" plugin battery calculation based on user feedback
- Code fixes: unhandledRejections CloudOn/Off for sockets and P1
v3.6.71
- Finetuning polling and capability during init phase of various drivers
- Added more logging to support diagnostic reports
- Bugfix SDM230 solar parameter was undefined
- Added an estimate charge available in plugin battery value
- Extra code checking for Homewizard Legacy (getStatus function) when there is a connection failure/device not found
v3.6.67
- Enforcing interval clears on various devices when interval is reset
- try_authorize handler bugfix (interval / timeout) app crash logs
v3.6.66
- Fall back url setting upon initial poll for P1, sockets, kwh's, watermeter. (older Homey Pro;s 2016/2019 seems to struggle with mDNS updates)
- Removed retry code for Homewizard legacy devices (changed to keeping http agent session open / keepAlive)
- Battery Group data removed from P1 after a fetch fail (bugfix)
- Increased timeouts (authorize / pairing APIv2)
- Language adjustment P1 warning (overload EN/NL) NOTE: First time running this version will fail as the url setting is empty so it should improve onwards.
v3.6.63
- SDM230 (p1 mode added)
- P1apiv2 - added daily usage kwh (resets at nightime) (does not cater for directly consumed solar-used energy as this does not pass the smart meter at all)
- Adjustment for P1 to look at Amp datapoints to detect 3-Phased devices in Norway
- HTTP - keepalive agent added to P1, sockets, APIv2 devices
- KeepAlive timeout increased from default 1000ms
- AbortController code added for APiv2
- Wifi quality capability added (-48dBm is not always clear to users if it is good or bad)
- Bugfix: P1, missed setAvailable(). Code didn’t recover from a failed P1 connection and kept P1 offline
v3.6.58
- Bugfix that was caused by experimental firmware Homey 12.5.2RC3 and slider capability that could not be removed
- Added energy flags for sockets so they can trace imported/exported energy in Homey Energy Dashboard (Home Batteries connected via sockets)
- Code cleanup
- Added some fine tuning to spread the API call's to the P1
v3.6.50
- Added phase monitoring
- Adjust settings to align with your energy grid
- Bugfix for sliders when gridconnection has 3 phases
- Actual gas meter measurement added (5min poll pending on smartmeter)
- P1apiv1 - Code refactored (clean up repetive lines)
- Extra plugin battery trigger cards (state change, time to full, time to empty)
- Removed sliders in GUI to show grid load per phases
v3.6.40
- Cloud connection setting made available for P1, Sockets, Watermeter, SDM230, SDM630
- Bugfix Offset watermeter (Cannot read properties of undefined - reading 'offset_water')
v3.6.38
- P1(apiv2) gas meter bugfixes
- P1(apiv2) aggregated total usage added (support for PowerByTheHour app)
- Custom polling for Watermeter, SDM230, SDM630 and SDM630-p1 mode, Default 10s, adjust in advanced settings
- Action cards plugin battery - P1apiv2 device is required (P1 firmware version 6.0201 or higher)
- Wifi metric (dBm) added for P1(apiv2) and Plugin Battery
- Custom Polling interval added for Plugin Battery
- Daily usage imported power and gas (P1apiv1) - User request
- Plugin Battery: added time_to_empty and time_to_full (minutes)
- Trigger for battery mode change
v3.6.6
- Homey Energy - Polling interval for all Energy devices (P1, kwh etc.) lowered to 1s (was 10s)
- Reverted interval back 10s as this has an increased load on some wifi networks and (older) homeys (Early2019)
v3.6.2
- Massive code rework (credits to DCSBL for time and effort)
- Homey Energy dashhboard: Energylink meter_gas capability added
- Text fix in Plugin Battery driver
- APIv2 timer timeout problem
v3.5.5
- Recode P1 APIv2, improved pairing process (DCSBL)
- Pairing process P1 and Plugin Battery aligned
- Plugin in Battery pairing text fix
v3.5.2
- SDM630 clone added to allow P1 like use of kwh meter as a replacement for P1 dongle (users request)
- Conversion to homey-compose (DCSBL)
- Socket identification with LED blink (DCSBL)
If you find this app useful, consider supporting development:
This app is licensed under the GNU General Public License v3.0
- Jeroen Tebbens - Main developer
- DCSBL - Major code contributions (homey-compose, pairing improvements)
- Sven Serlier (smarthomesvan) - Cloud API research, Legacy device improvements
- Community contributors - Bug reports and feature requests