Tested on AF9.99K-TH.

To charge a battery from the grid:

  • switch.inverter_battery_charge_discharge = on
  • select.inverter_meter = "Meter"
  • number.inverter_timed_charging_power > 0
  • number.inverter_timed_max_charge > current battery %
  • Current time within one of the timed charge windows
  • switch.inverter_timed_ac_charging = on

Makes use of new writeback functionality, usable from pre-release: v25.12.20.

@Juinjer Juinjer changed the title add controls for charging from the grid to afore T6 batteries add controls for charging from the grid to afore T6 inverters Dec 29, 2025
@davidrapan davidrapan changed the title add controls for charging from the grid to afore T6 inverters Add grid charging configurables ❘ Afore T6 Jan 1, 2026