fix: SG3.6RS missing registers#180

Open
JorgHendriks wants to merge 1 commit intobohdan-s:mainfrom
JorgHendriks:bug-registers_SG3.6RS
Open

fix: SG3.6RS missing registers#180
JorgHendriks wants to merge 1 commit intobohdan-s:mainfrom
JorgHendriks:bug-registers_SG3.6RS

Conversation

@JorgHendriks
Copy link
Copy Markdown

SG3.6RS was missing in the model list for particular addresses in the register.
As a result not all available values were exposed, most notably 5031, total_active_power that is part of the config example for mqtt export.

Fix: added SG3.6RS to all entries where SG3.0RS and SG4.0RS were listed (same model family).

Level 2 output after this fix:

+----------------------------------------------------------------------+
| Address | Register                            | Value                |
+---------+-------------------------------------+----------------------+
| ----    | device_type_code                    | SG3.6RS              |
| vr001   | run_state                           | ON                   |
| vr003   | last_reset                          | 2024-5-22 16:56:13   |
| vr006   | daily_export_to_grid                | 0.0 kWh              |
| vr007   | daily_import_from_grid              | 0.0 kWh              |
| 5001    | nominal_active_power                | 3.7 kW               |
| 5002    | output_type                         | 2P                   |
| 5003    | daily_power_yields                  | 7.6 kWh              |
| 5004    | total_power_yields                  | 7.6 kWh              |
| 5006    | total_running_time                  | 6 h                  |
| 5008    | internal_temperature                | 39.6 °C              |
| 5009    | total_apparent_power                | 2655 VA              |
| 5011    | mppt_1_voltage                      | 319.3 V              |
| 5012    | mppt_1_current                      | 8.6 A                |
| 5013    | mppt_2_voltage                      | 40.6 V               |
| 5014    | mppt_2_current                      | 0.0 A                |
| 5017    | total_dc_power                      | 2740 W               |
| 5019    | phase_a_voltage                     | 243.7 V              |
| 5020    | phase_b_voltage                     | 0.0 V                |
| 5021    | phase_c_voltage                     | 0.0 V                |
| 5022    | phase_a_current                     | 11.0 A               |
| 5031    | total_active_power                  | 2606 W               |
| 5033    | total_reactive_power                | -4 Var               |
| 5035    | power_factor                        | 1.0                  |
| 5036    | grid_frequency                      | 50.08 Hz             |
| 5038    | work_state_1                        | Run                  |
| 5049    | nominal_reactive_power              | 2.2 kVar             |
| 5071    | array_insulation_resistance         | 2432 k-ohm           |
| 5077    | active_power_regulation_setpoint    | 3700 W               |
| 5079    | reactive_power_regulation_setpoint  | 0 Var                |
| 5081    | work_state_2                        | Run                  |
| 5113    | daily_running_time                  | 371 min              |
| 5128    | monthly_power_yields                | 7.6 kWh              |
| 5146    | negative_voltage_to_the_ground      | 0.0 V                |
| 5147    | bus_voltage                         | 383.7 V              |
| 5150    | pid_work_state                      | None                 |
| 5151    | pid_alarm_code                      | None                 |
| 5216    | export_power                        | 0 W                  |
| 5218    | power_meter                         | 0 W                  |
| 7013    | string_1_current                    | 0.0 A                |
| 7014    | string_2_current                    | 0.0 A                |
| 7026    | string_14_current                   | 0.0 A                |
| 5006    | start_stop                          | Start                |
| 5007    | power_limitation_switch             | Enable               |
| 5008    | power_limitation_setting            | 100.0 %              |
| 5019    | power_factor_setting                | 0.0                  |
| 5035    | night_svg_switch                    | Disable              |
| 5036    | reactive_power_adjustment_mode      | Off                  |
| 5037    | reactive_power_percentage_setting   | 0.0 %                |
| 5039    | power_limitation_adjustment         | 3.7 kW               |
| 5040    | reactive_power_adjustment           | 0.0 kVar             |
| 5041    | pid_recovery                        | Disable              |
| vr002   | timestamp                           | 2024-5-22 17:01:13   |
| vr004   | export_to_grid                      | 0 W                  |
| vr005   | import_from_grid                    | 0 W                  |
+----------------------------------------------------------------------+
Logged 55 registers to Console