Notifications
You must be signed in to change notification settings - Fork 97
Climate configuration
Climate entities are developed for WHO 4
There are 3 distinct ways to configure this part depending on your setup.
In a 99 zones setup, the central unit needs to have the address #0, and all subordinate zones have their own number with and are NOT standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
standalone is an optional boolean defaulting to False, you can either ignore it or set it manually to False when you have a 99 zones setup
climate:
central_unit:
zone: '#0'
name: Central unit
heat: True
cool: False
standalone: False
manufacturer: BTicino
model: 3550
zone_1:
zone: '1'
name: Living room
heat: True
cool: False
standalone: False
manufacturer: BTicino
model: F430/4When you use a 4 zones central unit, the central unit itself acts as a separate zone, so it has a zone number configured; all subordinate zones are standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
centralis an optional boolean defaulting toFalse that you need to set to True only for the zone that acts as the central unit in your 4 zones setup
standalone is an optional boolean defaulting to False that you need to set to True for all subordinate zones in a 4 zones setup
climate:
central_unit:
zone: '1'
name: Central unit Living room
heat: True
cool: False
central: True
standalone: False
manufacturer: BTicino
model: HC4695
zone_2:
zone: '2'
name: Bedroom
heat: True
cool: False
standalone: True
manufacturer: BTicino
model: F430/4With no central unit, all zones are set as standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
standalone is an optional boolean defaulting to False that you need to set to True for all zones when you don't have any central unit
climate:
zone_1:
zone: '1'
name: Living room
heat: True
cool: False
standalone: True
manufacturer: BTicino
model: H4691
zone_2:
zone: '2'
name: Bedroom
heat: True
cool: False
standalone: True
manufacturer: BTicino
model: H4691