A prototype single channel solenoid driver was developed for testing.
It is contained in the driver-v0 folder.
We will have 3 manifolds with 8 of these in a row that need to be driven with 12V and signalled with a TTL line. All the manifolds will act in unison.
- https://www.theleeco.com/product/lhd-series-2-way-control-solenoid-valve/
- 3 boards, 8 channels each
- 8 TTL inputs + GND
- 8 12V outputs
- 12V input on barrel jack
- Plug:
- https://www.digikey.com/en/products/detail/globtek-inc/CRP11856F00/16515770
- Cable Assembly 2.1mm ID, 5.5mm OD Jack, Right Angle to Wire Leads Round 6.0’ (1.83m)
- Jack:
- https://www.digikey.com/en/products/detail/cui-devices/PJ-063AH/2161208
- PJ-063AH Power Barrel Connector Jack 2.10mm ID (0.083”), 5.50mm OD (0.217”) Through Hole, Right Angle
- Plug:
- LHDB1242115H
- Spike+hold voltage: 12, 7.2
- LOHM RATE** (Cv): 1500 Lohms (0.013)
- Power Consumption At Hold Voltage (mW): 310
- Response time: 10 ms Max
| # | Reference | Qty | Value | PartNum | Mfg |
|---|---|---|---|---|---|
| 1 | C1 | 1 | 47uF | T491X476K035AT | Kemet |
| 2 | C3 | 1 | 10uF | CL32A106KLULNNE | Samsung Electro-Mechanics |
| 3 | C4 | 1 | 0.18 uF | 08053C184KAT2A | KYOCERA AVX |
| 4 | C5 | 1 | 470pF | C0805C471K5RAC7800 | Kemet |
| 5 | D1 | 1 | LED | 150080RS75000 | Wurth |
| 6 | D2 | 1 | PMEG10010ELRX | PMEG10010ELRX | Nexperia |
| 7 | F1 | 1 | 0ZCF0125FF2C | 0ZCF0125FF2C | Bel Fuse |
| 8 | J1, J2 | 2 | Screw_Terminal_01x02 | 282837-2 | TE |
| 9 | J3 | 1 | Barrel_Jack | PJ-063AH | CUI |
| 10 | R1 | 1 | 49R9 | RC0805FR-0749R9L | Yageo |
| 11 | R2 | 1 | 191k | RC0805FR-07191KL | Yageo |
| 12 | R3 | 1 | 162k | RC0805FR-07162KL | Yageo |
| 13 | R4, R5 | 2 | 4k7 | RC0805JR-074K7L | Yageo |
| 14 | U1 | 1 | DRV104PWP | DRV104PWP | TI |
We will also have a pair of these valves that need to be driven by a single TTL line in opposition (if one is in state A the other should be in state B).
- LHDA1231415H
- https://www.theleeco.com/product/lhd-series-3-way-control-solenoid-valve/
- One TTL input + GND
- Two 12V complementary outputs
The solenoids should be driven with a high-side switch using a peak and hold circuit.