forked from Washington-University/HCPpipelines
-
Notifications
You must be signed in to change notification settings - Fork 0
Home
bstavel edited this page Apr 6, 2018
·
9 revisions
Welcome to the PanLab HCP Pipelines wiki! Forked from WashU ~Nov 16
Settings
Pre FreeSurfer: AvgrdcSTRING="NONE" TE="2.46" T1wSampleSpacing="0.000011999" # For General Electric scanners, 1/((0018,0095)(0028,0010)) T2wSampleSpacing="0.000008000" # For General Electric scanners, 1/((0018,0095)(0028,0010)) Tempaltes: Use .8mm MNI templates Brain Size = 150 FreeSurfer
No changeable settings
Post FreeSurfer
GrayordinatesResolutions="2" #Usually 2mm, but will we need to change this since our functionals are 2.46
HighResMesh="164" #Usually 164k vertices
LowResMeshes="32" #Usually 32k vertices, if multiple delimit with @, must already exist in templates dir
SubcorticalGrayLabels="${HCPPIPEDIR_Config}/FreeSurferSubcorticalLabelTableLut.txt"
FreeSurferLabels="${HCPPIPEDIR_Config}/FreeSurferAllLut.txt"
ReferenceMyelinMaps="${HCPPIPEDIR_Templates}/standard_mesh_atlases/Conte69.MyelinMap_BC.164k_fs_LR.dscalar.nii"
RegName="MSMSulc" #MSMSulc is recommended
Generic Volume:
DwellTime= ".001600" #Echo Spacing or Dwelltime of fMRI image, set to NONE if not
used. Dwelltime = 1/(BandwidthPerPixelPhaseEncode * # of phase encoding samples): DICOM field (0019,1028) =
BandwidthPerPixelPhaseEncode, DICOM field (0051,100b) AcquisitionMatrixText first value (# of phase encoding
samples).
DistortionCorrection="TOPUP" # TOPUP is recommended, though there are GE specific options
FinalFMRIResolution="2" #Marked by an if statement for 1 or 2-- stick with 2 but investigate the resolution of
mni space. #Target final resolution of fMRI data. 2mm is recommended for 3T
HCP data, 1.6mm for 7T HCP data (i.e. should match acquired resolution). Use 2.0 or 1.0 to avoid standard FSL
templates
GradientDistortionCoeffs="NONE", not as big an issue with GE scanners, or so was told by Adam and Hua.
BiasCorrection="NONE" #Outdated and not used in Lifespan. Cut the scans necessary for this in early iterations
Generic Surface Volume:
LowResMesh="32" #Needs to match what is in PostFreeSurfer, 32 is on average 2mm spacing between the vertices
on the midthickness
FinalfMRIResolution="2" #Needs to match what is in fMRIVolume, i.e. 2mm for 3T HCP data and 1.6mm for 7T HCP
data
SmoothingFWHM="2" #Recommended to be roughly the grayordinates spacing, i.e 2mm on HCP data
GrayordinatesResolution="2" #Needs to match what is in PostFreeSurfer. 2mm gives the HCP standard
grayordinates space with 91282 grayordinates. Can be different from the FinalfMRIResolution
RegName="MSMSulc" #MSMSulc is recommended
Task fMRI
critical_z: based on design matrix, estimated
dwell time: for pre-stat analysis, defaults to .7, not relevant for PanLab use
highpass temporal filtering: 200 default in connectome, will continue to use 200