Skip to content

Releases: SICKAppSpaceCodingStarterKit/CSK_Module_MultiIOLinkSMI

v3.4.0

15 Dec 09:37
d5776ac

Choose a tag to compare

Release 3.4.0

New features

  • Possibility to add a prefix and postfix for write messages

Improvements

  • Plain text search is used now for pattern search
  • Automatically set a pattern search within read message when selecting single process data or parameter
  • Improved handling if connecting SLT device

v3.3.0

31 Oct 13:59
8fb0767

Choose a tag to compare

Version 3.3.0

Improvements

  • Show result of pattern search within the IO-Link payload on UI
  • Show status info of IODD Interpreter on UI

v3.2.0

11 Aug 14:14
e284fbe

Choose a tag to compare

Release 3.2.0

New features

  • New function to edit amount of extra bytes to add to process data byte length

Improvements

  • FlowConfig handling

v3.1.0

03 Jun 11:38
e2919b5

Choose a tag to compare

Release 3.1.0

New features

  • OnNewRawReadMessage_INSTANCE_PORT_MESSAGENAME provides timestamp as 2nd event parameter (used for FlowConfig)

Improvements

  • Minor docu improvements
  • Minor update of readMessageName check

Bugfix

  • DeviceID was shown as ProductID in UI
  • 'OnNewDataAuto' FlowConfig block did not work with initial load of persistent data
  • Legacy bindings of ValueDisplay elements and FileUpload feature within UI did not work if deployed with VS Code AppSpace SDK
  • UI differs if deployed via Appstudio or VS Code AppSpace SDK
  • Fullscreen icon of iFrame was visible

v3.0.1

19 Feb 14:19
90df4a6

Choose a tag to compare

Release 3.0.1

Bugfix

  • Issue to create new instances (introduced with v3.0.0)
  • README update

v3.0.0

18 Feb 07:33
6f8ce5d

Choose a tag to compare

Release 3.0.0

New features

  • Provide features even without CSK_IODDInterpreter
  • Possibility to create readMessages without IODD information, by setting start-/endByte and unpack format
  • Possibility to search and cut relevant part out of created JSON within readMessage
  • New FlowConfig block 'OnNewDataAuto' which automatically creates readMessages and optionally checks to power selected port (WARNING: Do NOT mix with manual readMessage setup)
  • React on "OnStopFlowConfigProviders" event of FlowConfig modul to stop pulling IO-Link data
  • Check and handle different kind of IOLink.SMI APIs
  • Function to delete all existing readMessages
  • Check if persistent data to load provides all relevant parameters. Otherwise add default values
  • Selectable if timers for readMessages should start automatically after parameters were loaded

Improvements

  • Changed event name "OnNewReadMessage_PORT_MESSAGENAME" to "OnNewReadMessage_INSTANCE_PORT_MESSAGENAME" to make it possible to switch between ports during runtime
  • Do not start readMessage timers automatically with creation of readMessage
  • Use new event 'OnNewRawReadMessage_INSTANCE_PORT_MESSAGENAME" within FlowConfig (only providing data content as first parameter)
  • If using FlowConfig, start readMessage timers after 5 seconds
  • Add info about port within "OnNewIOLinkPortStatus" event
  • Add list of ports related to instances within "getInstancePortMap" function
  • Better handling if CSK_IODDInterpreter is not available

Bugfix

  • Issue with CSK_UserManagement support
  • Error if sending process data without any selection
  • Error in handling IODD data

v2.1.1

03 Feb 15:01
db14222

Choose a tag to compare

Release 2.1.1

Bugfix

  • Error if writing of process data and parameters (fix needs CSK_ModuleIODDInterpreter version >= 2.1.1)

v2.1.0

27 Jan 09:38
2915e76

Choose a tag to compare

Release 2.1.0

New features

  • Now it is possible to read subindexes (even if the subindex access is not supported). Requires IODD interpreter v2.1.0 or more

Improvements

  • Speeding up of data parsing when reading from IO-Link device

v2.0.0

28 Nov 11:41
015ece5

Choose a tag to compare

Release 2.0.0

New features

  • Supports FlowConfig feature to provide data of IO-Link ReadMessage
  • Changed event name of readMessages from 'readMessage[PORT][MESSAGENAME] to 'OnNewReadMessage_[PORT]_[MESSAGENAME]
  • Possible to pause timers for readMessages
  • Function 'getPort' for currently selected instance
  • Provide version of module via 'OnNewStatusModuleVersion'
  • Function 'getParameters' to provide PersistentData parameters
  • Check if features of module can be used on device and provide this via 'OnNewStatusModuleIsActive' event / 'getStatusModuleActive' function
  • Function to 'resetModule' to default setup

Improvements

  • Better interaction with CSK_IODDInterpreter (version 2.0.0 needed)
  • Check status of port within instance thread (prevent to get data if sensor is not in operating mode)
  • Port only changeable if currently inactive
  • New UI design available (e.g. selectable via CSK_Module_PersistentData v4.1.0 or higher), see 'OnNewStatusCSKStyle'
  • Preset names for ReadMessages / WriteMessages instead of renaming them after creation
  • check if instance exists if selected
  • 'loadParameters' returns its success
  • 'sendParameters' can control if sent data should be saved directly by CSK_Module_PersistentData
  • Added UI icon and browser tab information

Bugfix

  • IODD parsing
  • Check if readMessage exists before trying to delete it

v1.0.0

14 Feb 09:59
7ce455c

Choose a tag to compare

Initial version