Skip to content

Fix incorrect hvac_action when valveOpening = 0#253

Open
dinf60 wants to merge 1 commit intoMTrab:masterfrom
dinf60:fix_idle_heating
Open

Fix incorrect hvac_action when valveOpening = 0#253
dinf60 wants to merge 1 commit intoMTrab:masterfrom
dinf60:fix_idle_heating

Conversation

@dinf60
Copy link

@dinf60 dinf60 commented Sep 23, 2025

Problem
‒ Ally-komponenten bruger kun feltet work_state til at bestemme
hvac_action.
‒ Icon2 (fw ≥ 1.6) lader ofte work_state stå på Heat, selv om
ventilen er lukket (= ingen varme).
‒ Controlleren sender samtidig et mere pålideligt felt:
• output_status  (True = ventil åben) eller
• valveOpening (0 % = ventil lukket)

Løsning
Tjek først output_status / valveOpening; fald tilbage til
work_state, hvis de ikke findes.

@dinf60
Copy link
Author

dinf60 commented Sep 25, 2025

I forgot to mention that this PR will close issue #147.

@MTrab MTrab linked an issue Sep 25, 2025 that may be closed by this pull request
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

All room sensors constantly show as "heating" even though they are not

1 participant