Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Binary file not shown.
19,990 changes: 19,990 additions & 0 deletions docs/lumaswitch/files/LumaSwitch Assembly Public.step

Large diffs are not rendered by default.

Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added docs/lumaswitch/img/LumaSwitch_Cover.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
27 changes: 26 additions & 1 deletion docs/lumaswitch/index.md
Original file line number Diff line number Diff line change
@@ -1 +1,26 @@
# LumaSwitch
# LumaSwitch

![LumaSwitch](img/LumaSwitch_Cover.jpg){width="700"}

Five port passive PoE ethernet switch built specifically for the needs of FRC robots.

# Hardware Specs
* Same reliable buck-boost power stage of Luma P1
* 3.3V - 22.5V Input range
* Reverse polarity protection
* WAGO 2601 power input
* Five port 10/100 unmanaged switch
* 4X ports with optional unregulated PoE output
* Each port individually protected with a fuse
* LED indicator when PoE is active
* Remove fuse to disable PoE
* Versatile mounting
* \#10 through holes on 0.5" pitch
* Zip-tie notches
* Lightweight, less than 0.25lb with fuses installed

## Quick Links
* [Store Page](https://luma.vision/products/lumaswitch)
* [STEP file](files/LumaSwitch%20Assembly%20Public.step)
* [Mounting Diagram](files/LumaSwitch%20Assembly%20Public%20Drawing.pdf)
<!-- * [Enclosure 3D printing files]() -->
5 changes: 5 additions & 0 deletions docs/lumaswitch/mounting.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
# Mounting

LumaSwitch has four 5mm (0.2") through-holes in each corner of the device, on a 0.5" pitch. These holes can accomodate #10 or M4 bolts. The enclosure is electrically isolated, so there is no need to make sure your mount is isolated from the robot frame. Furthermore, LumaSwitch can also be mounted with zip ties using the notches on top of the enclosure.

![Mounting Diagram](img/LumaSwitch%20Assembly%20Public%20Drawing.jpg)
19 changes: 19 additions & 0 deletions docs/lumaswitch/wiring.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
# Wiring

## Powering LumaSwitch

LumaSwitch can be powered via unregulated battery voltage directly from the PDH/PDP/MPM via the Wago lever terminal. The lever terminal can accept 26 to 16 AWG wire. If you are using LumaSwitch to power other devices with PoE, 16 or 18 AWG wire is recommended, with a 20A fuse protecting the switch. If not using PoE, you can safely use any compatible wire with a 5A fuse.

When LumaSwitch is powered on, all ethernet status lights will blink once to indicate it is powered and working properly.

## Connecting Non-PoE Devices

LumaSwitch has one port that does not support PoE on the same side as the power input. This port is recommended to be used to connect LumaSwitch to the robot radio.

The other 4 ports can also be safely used with non-PoE devices, simply make sure there is no fuse installed for the ports you are using, and PoE output will be disabled for that port.

## Powering Passive PoE Devices
LumaSwitch can provide passive, unregulated PoE to up to 4 supported devices simultaneously, such as Luma P1. Enable PoE output on the desired ports by installing a 5A fuse for each port you would like to power a device with. The red "PoE" indicator LED will illuminate if PoE is being delivered and the installed fuse is good.

!!! note
Ensure that the fuses you use for PoE on LumaSwitch are each rated for a lower amperage than the fuse being used to protect the switch itself. This ensures that a short in one of the downstream devices will only blow its PoE fuse, not the fuse for the whole switch.
2 changes: 2 additions & 0 deletions mkdocs.yml
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,8 @@ nav:
- Spare Parts: p1/parts.md
- LumaSwitch:
- lumaswitch/index.md
- Mounting: lumaswitch/mounting.md
- Wiring: lumaswitch/wiring.md
markdown_extensions:
- attr_list
- admonition
Expand Down