correct RICH N2 flow rate, flow meter location#9
Open
tmlemon wants to merge 1 commit intoJeffersonLab:masterfrom
Open
correct RICH N2 flow rate, flow meter location#9tmlemon wants to merge 1 commit intoJeffersonLab:masterfrom
tmlemon wants to merge 1 commit intoJeffersonLab:masterfrom
Conversation
In "Services" subsection, corrected N2 flow rate and added text specifying that the nitrogen flow meters are outside of RICH on a gas panel.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
In "Services" subsection, corrected N2 flow rate. In "RICH Slow Control and Interlocks", added text specifying that the nitrogen flow meters are outside of RICH on a gas panel.
Changes can be reworded at reviewers' discretion.