This project provides a cross-platform command line interface (CLI) and graphical user interface (GUI) for controlling various radio scanner models through a unified interface. Built with PyQt6, the GUI allows users to interact with different scanner hardware using a consistent set of controls regardless of the manufacturer's native interface.
Scanner Controller bridges the gap between different scanner models by:
- Providing a universal interface for controlling scanners from different manufacturers
- Abstracting hardware differences through model-specific adapters
- Enabling remote control of scanners via a computer interface
- Enhancing the user experience with visual feedback and intuitive controls
- Standardizing commands across different scanner models
The application dynamically detects connected scanner models and loads the appropriate command adapter, making it easy to switch between different scanner hardware.
- Audio Controls: Adjust volume and squelch levels using sliders.
- Display Group: View scanner information on a simulated LCD display.
- Signal Meters: Monitor RSSI and squelch levels in real-time.
- Control Keys: Access frequently used scanner functions like "Hold", "Scan", "Menu", etc.
- Keypad: Input numeric values and commands using a keypad.
- Rotary Knob: Simulate a rotary knob for navigation and selection.
- Port Detection: Automatically detect and connect to supported scanner models via serial ports.
- Scanning Control: Start or stop scanning directly from the interface and access Close Call operations.
- Close Call Controls: Manage Close Call settings and jump commands through adapter helpers.
The following scanner models are supported through the commandLibrary:
- BC125AT: Uniden handheld scanner
- BCD325P2: Uniden handheld digital scanner
- Generic Uniden: Fallback adapter for other Uniden models. Unknown Uniden scanners automatically use this fallback with basic volume and squelch control.
The code is designed to work with most Uniden scanners and is abstracted to allow easy porting to other manufacturers.
The application follows a modular architecture:
┌───────────┐ ┌─────────┐ ┌─────────┐ ┌──────────┐
│ GUI / CLI │ <-- │ Scanner │ <-- │ Command │ <-- │ Scanner │
│ Interface │ --> │ Adapter │ --> │ Library │ --> │ Hardware │
└───────────┘ └─────────┘ └─────────┘ └──────────┘
- GUI/CLI Layer: User interface components that capture user input
- Scanner Adapters: Model-specific implementations that convert generic commands to hardware-specific protocols
- Command Library: Translates UI actions into scanner-specific commands
This separation allows new scanner models to be added without modifying the user interface.
The repository is organized into modules so new scanner models and features can be added easily:
scanner-controller/
├── adapters/ # Scanner model adapters
├── command_libraries/ # Command definitions for each model
├── scanner_gui/ # GUI application
│ ├── gui/ # PyQt widgets
│ └── icons/ # SVG resources
├── utilities/ # Shared utilities and helper scripts
├── tools/ # Miscellaneous scripts
├── dev_tools/ # Development utilities
├── tests/ # Unit tests
├── docs/ # Additional documentation
└── logs/ # Log files (git-ignored)
- Clone the repository:
git clone https://github.com/Boondock-Echo/scanner-controller.git
cd scanner-controller- (Recommended) Create and activate a virtual environment:
# On Unix/macOS
python -m venv .venv
source .venv/bin/activate
# On Windows
python -m venv .venv
.\.venv\Scripts\activate- Install dependencies:
pip install -r requirements.txtTo include optional HID support, install the package with the hid extra:
pip install .[hid]- Ensure the required scanner models are connected via serial ports.
Some scanners, such as the Uniden BC125AT, may appear as HID devices at
/dev/usb/hiddev* rather than traditional serial ports.
Run the helper script to load the USB serial driver and grant HID access:
tools/setup_hid.shLog out and back in, then verify detection with:
python tools/scanner_diagnostics.py --scanExpose the scanner as a serial port by loading the USB serial driver:
sudo modprobe usbserial vendor=0x1965 product=0x0017A /dev/ttyUSB* port should appear. Verify with:
dmesg | tail
python tools/scanner_diagnostics.py --scan-
Install the optional
hidlibrary via thehidextra:pip install .[hid]
-
Grant your user access to HID devices:
sudo usermod -aG plugdev $USER # log out and back in, or run: su - $USER
-
Ensure
/dev/usb/hiddev*paths are accessible. On Linux this may require additional drivers, udev rules, or group permissions.
Check kernel messages after plugging in the scanner:
dmesg | tailThen run the diagnostics tool to list available devices:
python tools/scanner_diagnostics.py --scanHID paths will be listed alongside serial ports once configured correctly.
After each change, re-run python tools/scanner_diagnostics.py --scan to confirm the device is detected.
Run the CLI version:
python main.pyOr launch the GUI:
python -m scanner_gui.mainUse the interface to select a serial port and control the scanner.
The CLI provides a custom search command to sweep a range of frequencies and
collect RSSI readings:
custom search <center> <span> <step><center>– center frequency of the sweep. Values may include a unit suffix (e.g.144M,144000k). Without a suffix, MHz is assumed.<span>– bandwidth to cover. Supports the same unit notation as<center>.<step>– step size between samples. Accepts either kHz or MHz notation (e.g.500kor0.5M). If no unit is specified, the value is interpreted as kilohertz.
The command returns pairs of (frequency, rssi) values. These readings can be
fed into a future GUI waterfall display for visual analysis of signal activity.
When selecting a preset or band without specifying a step size, the controller
uses conventional values defined in config/step_size_defaults.py. A few
examples are shown below:
| Band | Step (kHz) |
|---|---|
| air | 833 |
| race | 1250 |
| marine | 2500 |
| railroad | 1500 |
| ham2m | 2000 |
| ham70cm | 1250 |
| weather | 2500 |
| cb | 1000 |
| frs | 1250 |
| public_safety | 1250 |
| mil_air | 2500 |
The band select command configures the band scope using either a preset
name or explicit parameters. The shorter alias band set behaves the same.
> band select air
> band set 108M 136M 12.5k AM
After the BSP command is sent during band select, the scanner now
automatically enters band-scope search by issuing a scan-start key. It also
programs custom search range 1 using CSP and enables only that range with
CSG,0111111111 so the scope limits match the selected band. The CSP
command uses the preset limits in 100‑Hz units (e.g. 01080000 for 108 MHz)
to align with the scanner's expected format.
For the BC125AT, appending search to the band scope command performs a
slower sweep that polls the PWR command while the scanner runs a custom
search between the preset limits:
> band scope air search
The adapter programs range 1 using CSP/CSG, starts scanning, and records a
frequency/RSSI pair for each step. This method makes only a single pass across
the band and ignores the sweep-count parameter, so it is best suited for quick
checks rather than long captures.
Band scope status can be streamed using the CSC command. When activated the
scanner outputs lines of the form CSC,<RSSI>,<FRQ>,<SQL> for each hit. The
controller now processes data in sweeps. Each sweep gathers
band_scope_width records (falling back to 1024 if that width is unknown). The
CLI's band scope command takes a preset name followed by an optional sweep
count and mode; providing a number runs that many sweeps. Before streaming, the
total record count is calculated as band_scope_width * sweeps. After the final
record the command CSC,OFF is issued and the final CSC,OK response is read.
In list mode (the default) every (frequency, RSSI) pair collected during
the sweeps is printed. In hits mode the mean RSSI is computed and only
frequencies more than 20% above that mean are displayed. After all readings a
summary line describes the sweep parameters:
145.0000, 0.000
146.5200, 0.450
147.0400, 0.610
center=146.000 min=145.000 max=147.000 span=2M step=0.5M mod=FM
The related band sweep command streams the raw values directly. Each line
printed contains the frequency in megahertz and the normalized RSSI level:
<freq_mhz>, <rssi/1023.0>
For example: 162.5500, 0.450. This format is consistent in both human and
machine modes and is convenient for logging or further processing. Use the
optional mode argument to control output: list displays all values while
hits shows only entries 20% above the mean RSSI level:
> band scope <preset> [sweeps] [list|hits]
> band scope <preset> cc search
> band scope <preset> cc log
The cc search subcommand performs a Close Call search within the chosen
band and prints any hit frequencies after the search ends. Press Enter or
q at any time to terminate the search and restore the scanner's previous
settings. The cc log variant starts continuous logging of hits until
interrupted.
The utility function record_close_calls allows continuous logging of Close Call
hits to an SQLite database. Use the CLI command band scope <preset> cc log or
the legacy commands log close calls / log close calls lockout and provide a
band name such as air or frs. Each hit is saved with timestamp, frequency,
tone (if available) and RSSI level. When the lockout variant is used the
frequency is also added to the scanner's temporary lockout list via the LOF
command.
The logger normally runs indefinitely. To capture a limited number of hits or
stop after a set time, pass max_records or max_time to
record_close_calls:
from utilities.scanner.close_call_logger import record_close_calls
record_close_calls(adapter, ser, "air", max_time=10)The controller can maintain more than one active connection. The CLI now supports a small set of connection management commands:
list– show all open connections with the active one marked by*.scan– list detected scanners.connect <id>– connect to the scanner with the given ID (seescan).use <id>– make the specified connection active for subsequent commands.close <id>– disconnect and remove a connection from the list.
The older switch command is still accepted for scripts that relied on it, but
it closes the current connection before opening a new one. Using the new
commands keeps other scanners online and allows quick switching between them.
In the GUI, selecting a port while already connected spawns an additional window so multiple scanners can be controlled side by side.
Below is a short example showing band-scope streaming from two scanners:
$ python main.py
> scan
1. /dev/ttyUSB0 — BCD325P2
2. /dev/ttyUSB1 — BC125AT
> connect 1
Connected to /dev/ttyUSB0 [ID 1]
> connect 2
Connected to /dev/ttyUSB1 [ID 2]
> list
[1]* /dev/ttyUSB0
[2] /dev/ttyUSB1
> use 1
Using connection 1
> band scope 20 hits
(hits for scanner 1)
center=...
> use 2
Using connection 2
> band scope 20 hits
(hits for scanner 2)
center=...
To support a new scanner model:
- Create a new adapter class in the
adapters/directory. - Implement initialization, command processing, and cleanup logic.
- Register the adapter in the model detection code.
Example adapter skeleton:
class NewScannerAdapter(BaseAdapter):
def __init__(self, port: str):
self.port = port
self.connection = None
def initialize(self) -> None:
"""Establish connection with the scanner."""
# Initialize serial connection
def process_command(self, command: str, *args) -> None:
"""Convert generic commands to scanner-specific commands."""
if command == "SET_VOLUME":
... # send volume command
elif command == "SET_SQUELCH":
... # send squelch command
def read_response(self) -> str:
"""Read and interpret scanner responses."""
# Read from serial connection
def cleanup(self) -> None:
"""Close the connection and clean up resources."""
# Close connectionInstall development tools and pre-commit hooks:
pip install -r requirements-dev.txt
pre-commit installFormatting and linting are enforced with Black and Flake8. Run them before committing:
black .
flake8Useful scripts are located in tools/ and dev_tools/:
python tools/clear_pycache.py
python -m dev_tools.analyze_unused_files- Create and activate a virtual environment:
python -m venv .venv
source .venv/bin/activate # On Windows use .venv\Scripts\activate- Install development dependencies:
pip install -r requirements-dev.txt- Run the test suite:
pytest- Optionally run lint checks using the following commands:
black . --check
flake8
isort . --checkEnable verbose logging to troubleshoot serial issues:
import logging
logging.basicConfig(level=logging.DEBUG)You can also monitor serial traffic:
python -m scanner_gui.main --monitor-serial| Issue | Possible Solution |
|---|---|
| Scanner not detected | Verify cables and serial drivers |
| Commands not working | Check firmware and command syntax |
| GUI elements not responding | Restart the application and ensure PyQt is updated |
- Fork the repository.
- Create a branch for your feature or bugfix.
- Submit a pull request with a detailed description of your changes.