Hi,
I tested the analyzer sctech at my System.
My setuP is a Watturino with a ATmega328P-AUR and a lin Chip TJA1021
A difference to your scematic is a 30K resistor for the slave termination (LIN Standard)
I send the Message (configured as a Master) by PCAN-LIN of PEAK company.
If i send a message some ID's seem to be different.
sent | serial report
30 | f0
31 | b1
32 | 32
33 | 73
34 | b4
35 | f5
36 | 76
37 | 37
38 | 78
39 | 39
3a | ba
3b | fb
3c | 3c
3d | 7d
3e | fe
3f | bf
The characters of the mesage are ok, just a little scramble in th message ID.
Could this be caused by the resistor in my setup?
BR
Alf