Notifications
You must be signed in to change notification settings - Fork 15
Hourly NaturalGas output variable is incorrect #161
Description
Current Custom.pxt
...
Output:Variable,*,Site Outdoor Air Drybulb Temperature,hourly; !- Zone Average [C]
Output:Meter,Electricity:Facility,hourly; !- [J]
Output:Meter,Gas:Facility,hourly; !- [J]
! Zone
!Output:Variable,Perimeter_ZN_1,Zone Mean Air Temperature,hourly; !- Zone Average [C]
!Output:Variable,Perimeter_ZN_1.* Setpoint Schedule,Schedule Value,hourly; !- Zone Average []
...
Should be:
...
Output:Variable,*,Site Outdoor Air Drybulb Temperature,hourly; !- Zone Average [C]
Output:Meter,Electricity:Facility,hourly; !- [J]
Output:Meter,NaturalGas:Facility,hourly; !- [J]
! Zone
!Output:Variable,Perimeter_ZN_1,Zone Mean Air Temperature,hourly; !- Zone Average [C]
!Output:Variable,Perimeter_ZN_1.* Setpoint Schedule,Schedule Value,hourly; !- Zone Average []
...