getting endpoints /gateway , /system /heatingCircuits works like a charm, but getting the root fails with:

Error: HTTP_NOT_FOUND
at /usr/lib/node_modules/bosch-xmpp/lib/base-client.js:213:25
at tryCatcher (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/util.js:16:23)
at Promise._settlePromiseFromHandler (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/promise.js:547:31)
at Promise._settlePromise (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/promise.js:604:18)
at Promise._settlePromise0 (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/promise.js:649:10)
at Promise._settlePromises (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/promise.js:729:18)
at _drainQueueStep (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/async.js:93:12)
at _drainQueue (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/async.js:86:9)
at Async._drainQueues (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/async.js:102:5)
at Async.drainQueues [as _onImmediate] (/usr/lib/node_modules/bosch-xmpp/node_modules/bluebird/js/release/async.js:15:14)
at process.processImmediate (node:internal/timers:476:21) {
response: {
protocolVersion: 'HTTP/1.0',
statusCode: '404',
statusMessage: 'Not Found',
headers: {},
body: '\r\n'
}
}

I am not sure if it is an issue with bosch-xmpp or the interface in the cloud at bosch or the hardware

I have a Junkers MBLAN 2 connected to CW400 controller. (KUBC29

Unfortunately i can only guess the endpoints and found just three of them (all sub end points are accessibe as well):

/gateway
/system
/heatingCircuits

I cannot detect warm water device or the energy log (which is most interesting)

some more infos:

{"id":"/system/brand","type":"stringValue","writeable":0,"recordable":0,"value":"Junkers"...}
{"id":"/system/systemType","type":"stringValue","writeable":0,"recordable":0,"value":"NSC_ICOM_GATEWAY"...}
{"id":"/system/bus","type":"stringValue","writeable":0,"recordable":0,"value":"EMS2_0",...}
{"id":"/gateway/versionFirmware","type":"stringValue","writeable":0,"recordable":0,"value":"04.08.02"}
{"id":"/gateway/versionHardware","type":"stringValue","writeable":0,"recordable":0,"value":"iCom_Low_NSC_v1"}