Implementation of brighness control for the FLCOS displays.
Brighness is controled by pulling the corresponding potentials to high.
cable colors for reference:
- Vcc : red (3.3 - 5 VDC)
- GND : black
- AV : orange
- AV GND : white
- brighness + : blue
- brighness - : green
Note: Implementation should be done on powered bridge for simultaneous adjustment on both displays. Blue, green and Vcc need to be routed through the cable system. Check for spacing in heatbreaks. PCB might be in order for two additional buttons.