| Temperature and Humidity Sensor |
|---|
![]() |
These ZigBee node devices support ZHA standard protocol.
Linker ZigBee gateway module is one kind of Linker modules which can communicate with up to 32 ZigBee node devices. It is powered by Marvell 88MZ100 ZigBee microcontroller SoC chip. This ZigBee offers advantages for many application scenarios, including lighting control, smart metering, home/building automation, remote controls and health care applications.
This tutorial will introduce how to interface ZigBee temperature and sensor using the Linker ZigBee gateway.
Setting the temperature and humidity report are different.So we separate theses commands into two sections.
1. Set Permit Join
send: 02 75 1e
recv: 02 8a 00 recv: 0E FC 02 E1 B1 96 5E 59 39 53 C9 43 50 00 FF
Get the short address of device : B1 96
Get the MAC address of device : 5E 59 39 53 C9 43 50 00
2. Get the information
send: 04 c8 b1 96 01
recv: 19 C9 00 B1 96 14 01 04 01 02 03 00 05 00 00 03 00 02 04 01 00 09 00 01 19 00
3. set target
send: 0c fc 02 01 04 01 01 01 02 b1 96 02 0a
recv: 04 FD 02 01 00
4. Get the MAC address of ZiBee gateway
send: 02 14 6f
recv: 0C 15 00 6F 08 62 43 39 1F C9 43 50 00
Gateway Mac: 62 43 39 1F C9 43 50 00
5. Bind device to communication
send: 16 d8 5E 59 39 53 C9 43 50 00 01 02 04 03 62 43 39 1F C9 43 50 00 01
recv: 02 D9 00
6. Configure report
send: 11 fc 00 02 04 06 01 00 00 00 29 05 00 05 00 01 00 00
recv: 06 FD 00 02 04 06 00
7. Temperature report message
recv: 14 FE 03 02 04 0A 01 02 B1 96 00 96 00 01 00 00 00 00 29 F5 0A
Temperature is : 0x0AF5/100=28.05℃
1. Set Permit Join
send:02 75 1e
recv: 02 8a 00 recv: 0E FC 02 E1 1B 37 5E 59 39 53 C9 43 50 00 FF
Get the short address of device : 1B 37
Get the MAC address of device : 5E 59 39 53 C9 43 50 00
2. Get the information
send: 04 c8 1b 37 01
recv: 19 C9 00 1B 37 14 01 04 01 02 03 00 05 00 00 03 00 02 04 01 00 09 00 01 19 00
3. set target
send: 0c fc 02 01 04 01 01 02 02 1b 37 02 0a
recv: 04 FD 02 01 00
4. Get the MAC address of ZiBee gateway
send: 02 14 6f
recv: 0C 15 00 6F 08 62 43 39 1F C9 43 50 00
Gateway Mac: 62 43 39 1F C9 43 50 00
5. Bind device to communication
send: 16 d8 5E 59 39 53 C9 43 50 00 02 05 04 03 62 43 39 1F C9 43 50 00 01
recv: 02 D9 00
6. Configure report
send: 11 fc 00 05 04 06 01 00 00 00 21 05 00 05 00 01 00 00
recv: 06 FD 00 05 04 06 00
7. Humidity report message
recv: 14 FE 03 05 04 0A 02 02 1B 37 00 37 00 01 00 00 00 00 21 FA 17
Humidity is :0x17fa/100=61.38%