Description
Describe the bug
Due to another machanism to enable the Fieldbus the module is not feasable in the current shape for the device SIM2000STE / SIM2000STC.
The device is using the following API to configure the Fieldbustype, before open the Fieldbus
FieldBus.Config.setProtocol("ETHERNETIP") -- or "PROFINETIO"
This snipped will do the job. getter and setter need to be adapted.
The UI is working as well if there is the variable fieldbus_Model.fbMode = 'EtherNetIP' set to the corresponding value.
`--- Function to create fieldbus communication handle
local function create()
-- Hier die Selection zu machen.
FieldBus.Config.setProtocol("ETHERNETIP")
--if fieldbus_Model.fbMode ~= 'DISABLED' then
if not fieldbus_Model.handle then
fieldbus_Model.handle = FieldBus.create(fieldbus_Model.parameters.createMode)
if fieldbus_Model.handle then
FieldBus.setMode(fieldbus_Model.handle, fieldbus_Model.parameters.transmissionMode)
_G.logger:fine("Successfully created Fieldbus handle.")
getInfo()
getStatus()
deregisterFieldbusEvents()
FieldBus.register(fieldbus_Model.handle, 'OnStatusChanged', handleOnStatusChanged)
FieldBus.register(fieldbus_Model.handle, 'OnNewData', handleOnNewData)
FieldBus.register(fieldbus_Model.handle, 'OnControlBitsOutChanged', handleOnControlBitsOutChanged)
if fieldbus_Model.fbMode == 'EtherNetIP' then
Script.register('FieldBus.Config.EtherNetIP.OnFieldbusStorageRequest', handleOnEtherNetIPFieldbusStorageRequest)
Script.register('FieldBus.Config.EtherNetIP.OnAddressingModeChanged', handleOnAddressingModeChanged)
Script.register('FieldBus.Config.EtherNetIP.OnInterfaceConfigChanged', handleOnEthernetIPInterfaceConfigChanged)
elseif fieldbus_Model.fbMode == 'ProfinetIO' then
Script.register('FieldBus.Config.ProfinetIO.OnFieldbusStorageRequest', handleOnProfinetIOFieldbusStorageRequest)
Script.register('FieldBus.Config.ProfinetIO.OnDeviceNameChanged', handleOnDeviceNameChanged)
Script.register('FieldBus.Config.ProfinetIO.OnInterfaceConfigChanged', handleOnProfinetIOInterfaceConfigChanged)
end
else
_G.logger:warning("Not able to create Fieldbus handle.")
end
else
_G.logger:fine("Handle already exists.")
end
--end
end
fieldbus_Model.create = create`
CSK module:
- Version: 1.1.0
AppSpace device used:
- Type: SIM2000-3L10A00 / but we need to take care about variants. Maybe SIM2000-3* is a good starting point.
- Firmware [e.g. ver1.3.0]
To Reproduce
Steps to reproduce the behavior:
- Go to '...'
- Click on '....'
- ...
- See error
Expected behavior
A clear and concise description of what you expected to happen.
Screenshots
Additional context