Skip to content

RELAP5 to TRACE Conversion - TRACE Webinar 04 - TDV/TDJ conversion to TRACE FILL #125

@WDunsford

Description

@WDunsford

RELAP5/MOD3 MIT Pressurizer input model conversion to TRACE input. The RELAP5 input model uses a TDV and a TDJ at the inlet to a pipe component. The TDV is a constant pressure and temperature. The TDJ uses a time versus mass flow table. The TRACE FILL component that is a result of the conversion of the TDV and TDJ is a type 6 FILL which is a generalized state versus independent-variable form table. It looks like there is a one-for-one conversion of the numbers, but the mass flow from the TDJ is not converted to mass flow in the FILL component. It is entered in as a velocity, i.e. a mass flow of 0.41 kg/s in the TDJ table is converted to 0.41 m/s in the FILL table. The FILL type (6) indicates the generalized table is looking for velocities. Since the TDV is a constant pressure and temperature, the FILL type should be 5, which is a mass flow vs independent-variable form table. 

MIT-Prizer-R5.zip

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions