Notifications
You must be signed in to change notification settings - Fork 18
Description
Lio crashes when running PBE0 from Amber with a segmentation fault right before the link atoms managing part.
Lio also crashes when running normal PBE closed shell, but in such case it can find built in fitting basis sets.
jcordova@xg04:/tmp/jcordova_test/Test_openshell$ tail test.out
eefld_timegfh = F, eefld_timegih = F, eefld_wavelen = 0.00000000
! -- Fock Bias Potentials: -- !
fockbias_is_active = F, fockbias_is_shaped = F, fockbias_timeamp0 = 0.00000000,
fockbias_timegrow = 0.00000000, fockbias_timefall = 0.00000000,
fockbias_readfile = atombias.in
LIO initialisation.
Error: Fitting set file
/usr/local/easybuild/software/lio/1.2-libint2.6.0-fosscuda2020a/dat/basis/fitting/DZVP Coulomb Fitti
not found.
This error happens in lioamber/basis_data.f90 however there are no differences in this file with respect to the branch before the merge.
Develop before the merge does have the seg fault with PBE0 open shell but not the fitting basis set error of PBE closed shell.