Hello,

I have a qustion regarding distCase_test13nodes: Except for the slack bus(number 600), all the other buses are PQ buses. meaning, befor solving the power-flow, at these buses the values of P,Q are known and after solving the PF the mag and phase of the voltage are discoverd.
Now if I want to change these knwon values of P,Q before solving the PF, I just can't find anywhere in the project the values of P,Q at each bus(excpt bus 600) even though they are already known before the solution is made.

In busInfo in "output variable" P,Q appears directly thanks to the real and imag parts of the variable Sbus_MVA. However, at distCase_test13nodes there are Wye-load,Delta-load,Line branch data... but there is no field of caseObject wich holds the values of P,Q directly as Sbus_MVA does.

Any help appriciated!

p.s. what are nodes 1-10? I don't recognize nodes with these numbers from the official IEEE PES 13 node test feeder.