Notifications
You must be signed in to change notification settings - Fork 15
Open
Labels
bugexternal needresolving the issue needs external updates on dependenciesresolving the issue needs external updates on dependencies
Milestone
Description
At the moment, samtools mpileup gives an "=" at the end of some insertions, and we have opened an issue for that.
This results in such a line in the VCF, were ALT contains (or is) an equal:
#CHROM POS ID REF ALT QUAL FILTER INFO FORMAT IonXpress_005 IonXpress_019 IonXpress_020 IonXpress_030 IonXpress_053 IonXpress_104 IonXpress_105
chr11 62397115 . - = 152.793 . TYPE=ins;NS=103;AF=0.00970874;DP=43980;RO=37749;AO=10;SRF=17260;SRR=20489;SAF=5;SAR=5;SOR=0.536285;RVSB=0.542758;FS=0;ERR=5.01679e-05;SIG=0.001;CONT=ATGxCCC;AC=0;AN=14 GT:QVAL:DP:RO:AO:AF:SB:SOR:RVSB:FS:QVAL_minAF:STATUS 0/0:0:202:177:0:0:112,65,0,0:-1:-1:0:1217.54:. 0/0:0:298:248:0:0:120,128,0,0:-1:-1:0:1850.99:. 0/0:0:306:244:0:0:99,145,0,0:-1:-1:0:1879.87:. 0/0:0:469:414:0:0:181,233,0,0:-1:-1:0:2952.58:. 0/0:0:401:349:0:0:138,211,0,0:-1:-1:0:2512.24:. 0/0:0:672:557:0:0:229,328,0,0:-1:-1:0:inf:. 0/0:0:713:623:0:0:322,301,0,0:-1:-1:0:inf:.
Either it is a bug from samtools and we just need to wait for their bug resolving or we need adapt the mpileup2readcounts script.
Metadata
Metadata
Assignees
Labels
bugexternal needresolving the issue needs external updates on dependenciesresolving the issue needs external updates on dependencies