From 712cd713493d971a64330d7e7f7a56f5008c8a84 Mon Sep 17 00:00:00 2001 From: okke Date: Fri, 6 Mar 2026 22:18:49 +0100 Subject: [PATCH] Add uptime, MCU temperature, firmware version and IP sensors to Open AIR Mini These diagnostic entities are already present in the Open AIR Valve firmware but were missing from the Open AIR Mini. Adds uptime, internal MCU temperature, ESPHome firmware version, and WiFi IP address, all under entity_category: diagnostic so they appear in the Diagnostic tab in Home Assistant. --- Open AIR Mini/Software/open-air-mini.yaml | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+) diff --git a/Open AIR Mini/Software/open-air-mini.yaml b/Open AIR Mini/Software/open-air-mini.yaml index c26b3ab..3e150a1 100644 --- a/Open AIR Mini/Software/open-air-mini.yaml +++ b/Open AIR Mini/Software/open-air-mini.yaml @@ -154,6 +154,24 @@ sensor: entity_category: "diagnostic" device_class: "" + - platform: uptime + name: "Uptime" + entity_category: diagnostic + + - platform: internal_temperature + name: "MCU Temperature" + entity_category: diagnostic + +text_sensor: + - platform: version + name: "Firmware Version" + entity_category: diagnostic + + - platform: wifi_info + ip_address: + name: "WiFi IP" + entity_category: diagnostic + script: # Below includes for disconnected mode are mutually exclusive. Only use one at a time! !include disconnected-mode-without-humidity.yaml