When connecting using method = cisco, my switches are not returning the full config. Instead they show:
show running-config
Building configuration...
This is consistent across multiple switches in multiple locations. I tried on 3560X, 3750 and 6509 switch models. I originally thought it was a timeout issue but the same output is observed at 60, 120 and 180 second timeouts. The first run reports "exit status 128" and subsequent runs show "No changes" indicating the same output is returned. Also some are using the default user/pass while others I have overwrote the default login credentials.
This is on the latest v1.2 release. Native Junos is working great, though!